Clinical Trials Directory

Trials / Completed

CompletedNCT01604369

Cryoablation as Standard Treatment of Atrial Flutter

Cryoablation as Standard Treatment of Atrial Flutter - Long Term Efficacy and Patient Content

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
193 (actual)
Sponsor
Karolinska University Hospital · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The hypothesis of the present study is to evaluate cryoablation(cooling of the tissue) as standard therapy of common atrial flutter,focusing on efficacy, feasibility, procedure time, and patient content. The purpose of this study is to determine whether cryoablation, performed only by operators experienced in cryothermic ablation is effective and safe in the treatment of atrial flutter.

Detailed description

Atrial flutter (AFL), a common atrial tachyarrhythmia may cause significant symptoms and serious adverse effects including embolic stroke, myocardial ischemia and congestive heart failure. Currently, radiofrequency (RF) catheter ablation of the cavotricuspid isthmus (CTI) is considered first-line therapy for treatment of CTI-dependent AFL. However, RF ablation of the CTI is associated with significant pain during lesion delivery. Furthermore, RF ablation can potentially injure cardiac structures adjacent to the CTI such as the AV node, tricuspid valve and right coronary artery. RF ablation can also lead to steam pops, cardiac tamponade and fatal complications have also been reported in association with CTI-ablation. Ablation using cryothermal energy (Cryo) has several potential advantages over RF ablation including greater catheter stability due to adherence to myocardial tissue during applications, reduced risk of thrombus formation, systemic embolization, and lower risk of myocardial perforation due to preservation of tissue architecture. The investigators have in a prospective randomized, single centre study (CRAFT) investigated efficacy and safety of RF versus Cryo for atrial flutter, and showed that cryoablation is as effective as RF ablation in the short and long term. The patients perceived significantly less pain and required significantly lower doses of analgesia and sedation during cryoablation compared to RF ablation. The study was powered for non-inferiority with 75 patients in each group. The objective of the present study is to expand the findings from the CRAFT study in a larger cohort of patients, letting only operators experienced in cryothermic CTI ablation use Cryo as standard therapy focusing on efficacy, feasibility, procedure time, and patient content. To perform an ablation within the study, the electrophysiologist must have a previous experience of a minimum of 25 cryoablations of atrial flutter.

Conditions

Interventions

TypeNameDescription
PROCEDUREMedtronic Freezor Max Cardiac Cryoablation CatheterCryoablation is performed using a sequential application technique point-by-point from the tricuspid annulus to the inferior vena cava. Ablation is performed at a target temperature of -80 ºC. Each application will last for 240 seconds.

Timeline

Start date
2012-06-01
Primary completion
2016-06-01
Completion
2016-06-01
First posted
2012-05-23
Last updated
2016-10-06

Locations

1 site across 1 country: Sweden

Source: ClinicalTrials.gov record NCT01604369. Inclusion in this directory is not an endorsement.