Clinical Trials Directory

Trials / Withdrawn

WithdrawnNCT01546246

Water Method in Patients With Incomplete Colonoscopy

Water Method With Water Exchange Versus Air Insufflation in Patients With Incomplete Colonoscopy: a Prospective Randomized, Controlled Trial

Status
Withdrawn
Phase
N/A
Study type
Interventional
Enrollment
0 (actual)
Sponsor
Air Force Military Medical University, China · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Water method with water exchange has been shown to reduce medication requirement and pain experienced during colonoscopy. It increases the success rate of cecal intubation in sedated and unsedated patients undergoing screening colonoscopy. Exchange of water during scope insertion minimizes distension of the colonic lumen and decreases loop formation. Exclusion of air from the colon during insertion by omission of air insufflations and suction removal of residual air prevent elongation of the colon. These maneuvers facilitate colonoscopy insertion in average patients and may enhance the success of difficult colonoscopy. Colonoscopy has been considered the gold standard procedure in screening for colorectal disease. However, 5-10% of colonoscopies are incomplete due to patient discomfort, difficult anatomy and prior abdominal or pelvic surgery. The investigators postulate that these patients may benefit from using the water method for colonoscopy. In this proposal the investigators test the hypothesis that compared with conventional air insufflations the water method with water exchange significantly enhances the success rate of cecal intubation in patients with immediately failed colonoscopy. The aim of the study is to compare the outcome of colonoscopy using the water method versus the conventional air method in patients with incomplete colonoscopy. The primary outcome is cecal intubation success rate. The secondary outcomes include cecal intubation time, maximum pain score during colonoscopy, overall pain score after colonoscopy and adenoma detection rate.

Conditions

Interventions

TypeNameDescription
OTHERWater colonoscopyColonoscopy will be performed without medications and aided by water infusion in-lieu of air insufflation during insertion of the colonoscope. The water infusion involves putting warm sterile water into the colon to open up the colon for advancement of the colonoscope until the end of the colon (cecum) is reached. The water is delivered through scope irrigation channel by an infusion pump equipped with a foot switch which will be controlled by the endoscopist. Infused water used to cleanse residual fecal matter will be suctioned as needed to clear the colonic lumen.

Timeline

Start date
2011-11-01
Primary completion
2014-11-01
Completion
2014-12-01
First posted
2012-03-07
Last updated
2016-03-25

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT01546246. Inclusion in this directory is not an endorsement.