Clinical Trials Directory

Trials / Completed

CompletedNCT01500434

The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of Long De Novo Coronary Artery Lesions (PLATINUM LL)

PLATINUM: A Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System (PROMUS Element™) for the Treatment of up to Two De Novo Coronary Artery Lesions - Long Lesion Sub-trial

Status
Completed
Phase
Phase 3
Study type
Interventional
Enrollment
102 (actual)
Sponsor
Boston Scientific Corporation · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to evaluate the safety and effectiveness of the PROMUS Element™ Everolimus-Eluting Coronary Stent System for the treatment of patients with up to 2 de novo atherosclerotic coronary artery lesions. The lesions can be longer than average-sized.

Detailed description

The wide-spread use of drug-eluting stents (DES) has evolved as standard of care in de novo lesions. The proposed study will evaluate the safety and effectiveness of PROMUS Element for the treatment of de novo atherosclerotic lesions in native coronary arteries. The study design is consistent with the draft guidance for industry titled, "Coronary Drug-Eluting Stents - Nonclinical and Clinical Studies" (March 2008). During the trial, thienopyridines must be administered according to the 2007 American College of Cardiology (ACC)/American Heart Association (AHA)/Society for Cardiovascular Angiography and Interventions (SCAI) guidelines, which recommended that clopidogrel (75 mg daily) or ticlopidine (250 mg twice daily) be prescribed after stent implantation for at least 6 months in all patients, and for at least 12 months in patients who are not at high risk of bleeding. For sites in the United States, the use of prasugrel is not allowed as part of the PLATINUM Clinical Trial. For sites in other countries, prasugrel may be prescribed according to its approved dosing in countries in which it is available. For patients taking aspirin daily a loading dose is recommended; for patients who have not been taking aspirin daily, aspirin must be administered as a loading dose. Patients continue to take aspirin indefinitely to reduce the risk of thrombosis. This PLATINUM Long Lesion study is a sub-trial associated with the PLATINUM Workhorse Randomized Controlled Trial, which is registered under NCT00823212.

Conditions

Interventions

TypeNameDescription
DEVICEPROMUS Element Coronary Stent SystemPROMUS Element is a device/drug combination product composed of two components, a device (coronary stent system including a platinum chromium stent platform) and a drug product (a formulation of everolimus contained in a polymer coating).
DRUGAspirinPatients are required to take aspirin indefinitely after stent implant. It is recommended that aspirin 162-325 mg daily be given for at least 6 months after stent placement and that aspirin 75-162 mg daily be given indefinitely thereafter.
DRUGThienopyridinePatients must be treated with one of the following thienopyridines for at least 6 months following the index procedure: clopidogrel 75 mg daily; or ticlopidine 250 mg twice daily; or prasugrel (outside the United States and if approved at the time of the procedure). If used, the prescribed dose should be in accordance with approved country-specific labeling. In patients not at high risk of bleeding, thienopyridine treatment should continue for at least 12 months after stent implant.

Timeline

Start date
2009-02-01
Primary completion
2011-03-01
Completion
2015-05-01
First posted
2011-12-28
Last updated
2019-03-26
Results posted
2012-02-14

Locations

30 sites across 7 countries: United States, Australia, Belgium, France, Japan, Latvia, New Zealand

Source: ClinicalTrials.gov record NCT01500434. Inclusion in this directory is not an endorsement.