Trials / Completed
CompletedNCT01489176
Regadenoson Real Time Perfusion Imaging Trial-Optison
Regadenoson Stress Real-Time Myocardial Perfusion Echocardiography for Detection of Coronary Artery Disease Feasibility and Accuracy of Two Different Ultrasound Contrast Agents
- Status
- Completed
- Phase
- Phase 3
- Study type
- Interventional
- Enrollment
- 50 (actual)
- Sponsor
- University of Nebraska · Academic / Other
- Sex
- All
- Age
- 30 Years
- Healthy volunteers
- Not accepted
Summary
The purpose if this study is to examine how effective Regadenoson is in detecting coronary artery disease during a stress echocardiogram when Optison is administered. Optison is a contrast agent that improves the images of the heart on the echocardiogram (echo) machine. Optison is approved by the Food and Drug Administration (FDA) to use during stress echocardiograms. Regadenoson is a commercially available rapid acting stress agent that is used to chemically increase the heart rate and is approved for nuclear imaging tests. Regadenoson is a FDA approved drug but not for the intended use in this study.
Detailed description
Stress perfusion imaging has primarily been done with radionuclide scintigraphy or single photon emission computed tomography (SPECT) and has not reached its full clinical potential because of the poor spatial resolution of SPECT, increased expense of this procedure, patient exposure to ionizing radiation, and lack of availability. The A2A receptor agonist Regadenoson has been utilized to detect myocardial perfusion abnormalities during SPECT myocardial perfusion imaging. A 100 patient pilot study (Regadenoson Real Time Perfusion Imaging Trial, IRB #566-08-FB) demonstrated the feasibility and accuracy of real-time perfusion echocardiography (RTPE) in detecting coronary artery disease following Regadenoson bolus injection and Definity as an ultrasound contrast agent. The aim of this study is to determine whether similar feasibility and accuracy can be achieved with Optison (a Food and Drug Administration approved ultrasound contrast agent that differs slightly in microbubble size and composition) in detecting coronary artery disease (CAD) following Regadenoson bolus injection. As with the original study, sensitivity, specificity, and accuracy of perfusion and wall motion analysis to identify a coronary stenosis \>50% in diameter by quantitative angiography will be analyzed.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DRUG | Regadenoson; Optison | A one-time intravenous bolus of Regadenoson 400 mcg; continuous intravenous infusion of Optison of 2-4 mL/minute. |
Timeline
- Start date
- 2012-07-31
- Primary completion
- 2014-04-01
- Completion
- 2014-12-01
- First posted
- 2011-12-09
- Last updated
- 2024-10-08
- Results posted
- 2022-12-30
Locations
2 sites across 1 country: United States
Regulatory
- FDA-regulated drug study
Source: ClinicalTrials.gov record NCT01489176. Inclusion in this directory is not an endorsement.