Clinical Trials Directory

Trials / Completed

CompletedNCT01454882

Measuring Free-living Energy Expenditure Using Direct Calorimetry

Status
Completed
Phase
Study type
Observational
Enrollment
39 (actual)
Sponsor
University of Colorado, Denver · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Accepted

Summary

Although instruments such as pedometers and heart rate monitors are helpful for those who use exercise to maintain their weight, they do not actually measure calories expended, which is a critical piece of information necessary for sustained weight management. The purpose of this study is to determine the accuracy of a new device that measures calories burned based upon heat produced by the body. Since heat production is directly proportional to calories burned, this device has the potential to accurately measure energy expended in many different settings.

Detailed description

Current approaches to measuring total daily energy expenditure (TDEE) in free-living individuals are limited by cost, accuracy, and lack of sensitivity to specific activities. Accurate, reliable, and low cost approaches for measuring TDEE are needed not only to improve clinical outcomes (e.g. weight management), but also to meet public health research objectives. In humans, EE is proportional to total heat loss, which is the sum of conductive, convective, radiant and evaporative heat flows, and measurement of heat loss is the basis of direct calorimetry. However, it has not been possible to accurately measure all forms of heat flux in free-living humans, particularly evaporative heat loss, which can be a substantial component of total heat production. A recently developed heat flow gauge with the capacity to measure all forms of heat flux has shown promise in proof of concept trials and pilot studies, but its accuracy in measuring TDEE has not yet been thoroughly tested. Moreover, how accuracy is affected by factors such as clothing, ambient temperature, and adiposity has not been studied. The objectives of the proposed research are to a) refine the measurement of TDEE based on total heat flux by determining how factors such as clothing, ambient temperature, age, sex, and body composition influence accuracy; b) compare the accuracy of this approach against the criterion measurements of Doubly Labeled Water (DLW) and whole-room indirect calorimetry; and c) compare the accuracy against a similar instrument that measures heat flux, but is not capable of directly measuring the evaporative component. The proposed research is innovative because it will test the accuracy of an approach that is based on a physiological signal (heat production) which is directly proportional to EE. In addition to accurately measuring TDEE, identifying and distinguishing different types of physical activity is an important goal of physical activity related research, but the capacity to do so is limited. Thus, an additional goal of the proposed research is to determine if measurement of changes in heat flux can be used to identify EE in specific bouts of activity and to differentiate between upper body and lower body activity. The proposed studies will permit refinement of a technology that will have major impact in both clinical practice and research. This new approach will potentially provide substantive improvements in the measurement of TDEE in free-living humans and in the assessment of physical activity and the associated energy cost.

Conditions

Interventions

TypeNameDescription
BEHAVIORALEffects of ClothingThere will be two temperature conditions; warm temperature \[WT, 75°F (24°C)\] and cool temperature \[CT, 60°F (16°C)\]. During each condition, subjects will vary the amount of clothing they are wearing at specified times
BEHAVIORALEffects of TemperatureThere will be two temperature conditions; warm temperature \[WT, 75°F (24°C)\] and cool temperature \[CT, 60°F (16°C)\]. During each condition, subjects will vary the amount of clothing they are wearing at specified times
BEHAVIORALLow Physical ActivityThis will be a randomized study with two within subject conditions (high and low physical activity levels)
BEHAVIORALHigh Physical ActivityThis will be a randomized study with two within subject conditions (high and low physical activity levels)
BEHAVIORALDirect calorimetry and doubly labeled waterTDEE will be measured simultaneously for 14 days using direct calorimetry and doubly labeled water. A heterogeneous sample of adult men and women in stable health will be studied.

Timeline

Start date
2012-01-01
Primary completion
2015-11-01
Completion
2016-01-01
First posted
2011-10-19
Last updated
2016-01-11

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT01454882. Inclusion in this directory is not an endorsement.