Clinical Trials Directory

Trials / Unknown

UnknownNCT01437176

Treatment of Intertrochanteric Fracture With New Type of Intramedullary Nail

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
50 (estimated)
Sponsor
Peifu Tang · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to determine whether this new intramedullary fixation is effective in the treatment of intertrochanteric fracture.

Detailed description

With the progress of aging society, elderly patients with intertrochanteric fractures were occurred more and more. The best recommend treatment is surgical treatment of intramedullary fixation. However, existing methods of intramedullary fixation could not be restored the integrated interior support, and it will occur early hip varus. Meanwhile, the varus deformity will no longer develop if the two ends contact with wach other. This new intramedullary fixation device can overcome the existing shortage of intramedullary fixation devices and supporting the inside of the problem. It can prompting the fracture site to obtain a stronger initial stability, improve fracture healing rate, reduce the incidence of varus and allow patients with early weight-bearing walking. This new type of intramedullary fixation of intertrochanteric fractures of devices, including a proximal femoral anatomy and adapt to proximal femoral nail, proximal femoral nail through the femoral head and distal femur compression screw locking screw, its main features are: 1. The proximal femoral nail was made from titanium, its proximal part is narrow inside and wide outside structure. It looks like a trapezoidal in cross-section. This device was matched with the anatomy of proximal femur and its mechanical reliability. 2. The tip of compression screw was designed thread. It can come through the intramedullary nail, produce slide and sustained pressure. 3. The femoral support screw was made in cylindrical, had a blunt rounded tip. The tip of the femoral support screw was tabling with the groove of compression screw. This design can support interior mechanical stability. At the same time, the support screw from the femoral head and neck compression screw can slide fine-tuning, so it has a direct offset against varus and femoral neck rotating shift to prevent secondary loss of fracture reduction. The screw in the femoral head also can prevent cutting occurs. 4. This device can be used in minimally invasive approach of percutaneous and implanted in body. Reduce reduction time, fracture interference and help the natural healing of fractures.

Conditions

Interventions

TypeNameDescription
DEVICEnew type of intramedullary nailThis is a new fixation treat for intertrochanteric fracture.
DEVICEThe intramedullary nail of PFNAIt was used very common in treat with intertrochanteric fracture.

Timeline

Start date
2011-09-01
Primary completion
2022-09-01
Completion
2024-08-01
First posted
2011-09-20
Last updated
2022-09-21

Locations

1 site across 1 country: China

Source: ClinicalTrials.gov record NCT01437176. Inclusion in this directory is not an endorsement.