Accuracy of Half of the Usual Radiotracer Dose in SPECT

Diagnostic and Prognostic Accuracy of Stress SPECT Myocardial Perfusion Imaging With Half the Usual Radiotracer Dose

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
18 (actual)
Sponsor
Ottawa Heart Institute Research Corporation · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

There has been a shortage of nuclear isotopes, not only in Canada but around the world. New, more sensitive SPECT cameras can obtain better images in shorter scan times. These cameras have also shown the ability to use a smaller dose of radioisotope to obtain the images. New software has been tested on the standard camera, the GE Infinia-Hawkeye SPECT/CT. The Diagnostic Imaging Department of The University of Ottawa Heart Institute has also acquired a new camera, the Discovery NM530c CZT and has been doing heart scans in shorter times. The investigators will now be looking at the quality of images using less isotope during SPECT myocardial perfusion imaging for diagnostic and prognostic purposes.

Detailed description

SPECT MPI is well accepted as a reliable and cost-effective tool for diagnosis, risk stratification and management of patients with suspected or known coronary artery disease (CAD) (1;2). MPI represents approximately 40% of nuclear medicine patient studies and most of these use 99mTc-sestamibi or 99mTc-tetrofosmin(3). Rest/stress MPI using 99mTc-sestamibi and 99mTc-tetrofosmin uses more tracer doses than many other nuclear medicine tests and thus account for \>50% of injected radiotracer activity(3). Thus, interruptions in the supply of 99Mo, the parent isotope of 99mTc, significantly affect stress MPI imaging and associated patient care. Alternatives to 99mTc-sestamibi and 99mTc-tetrofosmin for perfusion imaging include 201Tl for SPECT imaging and 82Rb or 13NH3 for positron emission tomography (PET) imaging (4;5). MPI using 201Tl has similar diagnostic accuracy but image interpretation is more difficult due to greater scatter and attenuation. Moreover, the patient effective radiation dose for MPI using a standard injected dose of 3.5mCi of 201Tl is \~20 mSv. This radiation dose is twice that of 99mTc tracers which typically deliver an effective dose of \~10 mSv. PET imaging with 82Rb or 13NH3 is another alternative, but is much more expensive and not routinely available in Canada due to a very limited install base of PET scanners and associated cyclotrons. The number of SPECT cameras operational in Canada is more than 40 times the number of PET scanners.

Conditions

Interventions

TypeNameDescription
RADIATION1/2 dose of 99mTc OR 201Tl tracersRest: Imaging will occur 30 to 60 minutes after injection of tracer. Stress: All patients will undergo a symptom-limited Bruce protocol treadmill exercise test. At peak stress, the radiotracer will be injected intravenously, and exercise will continue for an additional 60 s. The patients who are unable to achieve the targeted heart rate or exercise will be stressed pharmacologically. Dipyridamole (0.142 mg/kg/min) will be infused intravenously for 5 minutes, and 99mTc radiotracer will be injected at 2 min after infusion completion (7 min into the study). Aminophylline (100-200 mg) will be given intravenously 2 min after injection of the radiotracer.

Timeline

Start date
2010-04-01
Primary completion
2013-03-01
Completion
2014-09-01
First posted
2011-08-09
Last updated
2016-02-24

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT01412827. Inclusion in this directory is not an endorsement.