Trials / Completed
CompletedNCT01398865
Escitalopram Neuroimaging Supplement
Cerebral Metabolic Correlates of Treatment Response to Escitalopram in Body Dysmorphic Disorder
- Status
- Completed
- Phase
- —
- Study type
- Observational
- Enrollment
- 23 (actual)
- Sponsor
- Massachusetts General Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years – 64 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to find out more about the brain's response to selective serotonin reuptake inhibitor (SSRIs) treatment in people with body dysmorphic disorder (BDD). The investigators will use positron emission tomography (PET) and Magnetic Resonance Imaging (MRI) scans to look at brain activity in people with BDD before and after treatment with an SSRI. The investigators hope that what is learned will allow prediction of whether someone will improve with SSRI treatment.
Detailed description
The investigators have chosen to focus on five regions of interest, namely ACC, OFC, caudate, amygdala and hippocampus. These are brain regions that have been previously associated with obsessive-compulsive, affective, and psychotic phenomena. The investigators will test for correlations between pre-treatment FDG brain images and subsequent SSRI treatment outcome to identify potential predictors of treatment response. Finally, the investigators will compare pre-treatment and post-treatment PET FDG studies as well as MRI studies in BDD subjects to examine changes in these brain regions following treatment. The goals of the proposed research are to use FDG-PET and MRI to identify predictors of treatment response to SSRIs in BDD and to determine changes in rCMRglu in BDD subjects following treatment with SSRIs.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | PET scan and MRI scan | PET: The PET Scan is manufactured by Siemens and the model is the Exact HR+ .rCMRglu data will be gathered over a 30 minute resting period using a Siemens HR+ PET camera (4.5 mm in-plane and axial resolution). The total time for an individual PET session, will thus be one hour and a half (30 minutes for serum pregnancy test and 30 minute uptake period followed by 30 minutes of scanning). MRI: High-resolution scans will be acquired using a Seimens (manufacturer) 1.5T Avonta system at MGH, to be coregistered with subsequently acquired PET images, and used for A) delineation of regions of interest (ROIs), and B) facilitation of optimal transformation to MNI space. |
Timeline
- Start date
- 2008-12-01
- Primary completion
- 2013-03-01
- Completion
- 2013-03-01
- First posted
- 2011-07-21
- Last updated
- 2015-03-13
Locations
1 site across 1 country: United States
Source: ClinicalTrials.gov record NCT01398865. Inclusion in this directory is not an endorsement.