Paclitaxel-Coated Versus Uncoated Balloon for Treatment of Below-the-Knee In-Stent-Restenosis
- Status
- Withdrawn
- Phase
- Phase 3
- Study type
- Interventional
- Enrollment
- 0 (actual)
- Sponsor
- Herz-Zentrums Bad Krozingen · Academic / Other
- Sex
- All
- Age
- 50 Years – 90 Years
- Healthy volunteers
- Not accepted
Summary
There is both a poor life expectancy and a poor prognosis of limb salvage in those patience with stenoses or occlusions of the lower limb. To date only a small number of these patients could be helped through medication or surgery. The indications for stent placement are poor primary results following percutaneous transluminal angioplasty or evidence of a flow-limiting dissection. The primary success rate after a stent placement is between 80% and 90%. One so far inconsistent discussed problem is the occurrence of in-stent restenosis which is expected in 20% to 78% of treated lesions, depending on the stent used. Using only percutaneous transluminal angioplasty for treatment of an in-stent restenosis, restenosis reoccurs in 70% to 80% of cases. The aim of this study is to analyse the primary success and the long term results of angioplasty using the drug-coated balloon (paclitaxel) compared to an non-coated balloon in the treatment of in-stent restenosis of lower limb arteries.
Detailed description
In this prospective, double-blind, randomised, multi-centre study the use of the already certified coated balloon and an uncoated balloon is evaluated in patients with in-stent restenoses/reocclusions of the lower limb artery. The whole lesion length should be covered by the balloon so that proximal and distal overlap of the lesion by a minimum of 5mm is assured. Based on the current literature the average restenoses rate of the lower limb arteries after percutaneous transluminal angioplasty of an in-stent restenosis is 70% after 6 months. Assuming the restenosis rate reduces to 30% after percutaneous transluminal angioplasty using a drug-coated balloon, with a significance level of Alpha=0.05 (bilateral) and a power Beta=0.8, the enrolment of 100 patients is required in order to show a significant difference between treatment groups, considering a dropout rate of 30%. The choice of treatment will be distributed in a randomised, double blind procedure. The study duration per patient is 2 years. Clinical follow-up evaluations will take place after 3 and 6 months and after 1 and 2 years. After 3 month and 12 months an angiography of the target vessel will be performed.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | paclitaxel-coated balloon | Balloon is coated with paclitaxel in a concentration of 3µg/mm2. |
| DEVICE | non-coated balloon | percutaneous transluminal angioplasty with a non-coated balloon |
Timeline
- Start date
- 2012-04-01
- Primary completion
- 2013-09-01
- Completion
- 2014-09-01