Clinical Trials Directory

Trials / Completed

CompletedNCT01369381

Cervical Spine Biomechanics During Endotracheal Intubation

Intubation Mechanics of the Stable and Unstable Cervical Spine

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
14 (actual)
Sponsor
University of Iowa · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

Current methods for endotracheal intubation in the presence of cervical spine (c-spine) instability are not evidence-based. This is so because the relationships between the forces applied during intubation (by the laryngoscope) and the resulting c-spine movement have not yet been quantitatively characterized. As a result, with the current level of knowledge, it is not known, and it is not possible to predict, which types of c-spine instability have the greatest risk of cervical spinal cord injury with intubation. This shortcoming makes it impossible to know which intubation devices and techniques are likely to be safest in the presence of c-spine instability. To address this critical lack of knowledge, the overarching purpose of the proposed research is to: 1) quantitatively relate c-spine movement that results from the forces applied to the peri-airway tissues during intubation (force-motion relationships), and 2) use these data to develop a mathematical model of the c-spine that will predict which types of c-spine instability result in the greatest amount of abnormal c-spine motion and associated spinal cord compression during intubation. This clinical study will utilize laryngoscope blades that are instrumented with a high resolution pressure mapping system to make high-resolution measurements of the forces and pressures of intubation while making simultaneous measurements of c-spine motion. In this study, study subjects will be intubated using both a conventional (Macintosh) laryngoscope and an alternative (Airtraq) laryngoscope. By using two different laryngoscopes, we, the investigators, will introduce forces of differing magnitudes and distributions to peri-airway tissues. The Airtraq does not require a direct line of sight to visualize the vocal cords, and among the various new alternative laryngoscopes it is the only one that has been shown to result in 30-50% less cervical motion than a conventional (Macintosh) laryngoscope. Accordingly, we hypothesize 1) 30-50% less force will be applied with the Airtraq laryngoscope than with the conventional (Macintosh) laryngoscope and 2) 30-50% less c-spine motion will occur with the Airtraq. By studying (intubating) each subject twice, any differences in the c-spine force-motion relationships between devices will be due to the devices themselves. By studying each subject twice, we can account for (and eliminate) differences among study subjects in c-spine biomechanical properties.

Conditions

Interventions

TypeNameDescription
PROCEDUREEndotracheal intubationStudy patients undergo endotracheal intubation using both a conventional direct laryngoscope (Macintosh) and an alternative indirect laryngoscope (Airtraq). The order of intubation (Macintosh then Airtraq--or--Airtraq then Macintosh) is randomized.

Timeline

Start date
2011-12-01
Primary completion
2012-07-01
Completion
2012-07-01
First posted
2011-06-08
Last updated
2012-08-07

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT01369381. Inclusion in this directory is not an endorsement.