Trials / Unknown
UnknownNCT01324557
Insulin Pump Therapy and Continuous Glucose Monitoring in Diabetic Continuous Ambulatory Peritoneal Dialysis (CAPD) Patients
- Status
- Unknown
- Phase
- Phase 2
- Study type
- Interventional
- Enrollment
- 44 (estimated)
- Sponsor
- Guangdong Provincial People's Hospital · Academic / Other
- Sex
- All
- Age
- 18 Years – 70 Years
- Healthy volunteers
- Not accepted
Summary
The aims of this study are to assess the potential efficacy and safety of insulin pump to improve glycemic control in conjunction with continuous glucose monitoring (CGMS) for diabetic continuous ambulatory peritoneal dialysis (CAPD) patients.
Detailed description
Diabetic nephropathy now accounts for 20% to 40% of all patients entering end-stage renal failure (ESRF) programs. The quality of glycemic control is known to be an important determinant of the rate of progression of patients with diabetic continuous ambulatory peritoneal dialysis (CAPD) patients. Diabetic CAPD patients are usually treated with dialysis fluids utilizing glucose as the osmotic agent to provide ultrafiltration. Most of diabetic CAPD patients had HbA1c readings above 7% despite the recommendation to keep the reading below 7%. The continuous blood glucose monitor (CGMS) has recently offered an opportunity to monitor blood glucose at 5-minute intervals for 72 continuous hours in diabetic patients. The CGMS patterns reveal blood glucose tracings well above the recommended standards of control in most of the diabetic CAPD patients. Good glycemic control is often difficult to maintain in diabetic patients treated with CAPD because they are continuously exposed to high concentrations of glucose in peritoneal dialysate. However, recent studies have suggested that diabetic patients who use insulin pump has been shown to reduce glycated hemoglobin levels without an increased risk of hypoglycemia, as compared with a regimen of multiple daily insulin injections, but results in diabetic CAPD patients have not been reported.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | CSII and MDI | The aims of this study are to assess the potential efficacy and safety of insulin pump(MiniMed Paradigm® REAL-Time Revel™ Insulin Pump) to improve glycemic control in conjunction with continuous glucose monitoring (CGMS) for diabetic CAPD Patients. |
Timeline
- Start date
- 2011-03-01
- Primary completion
- 2013-12-01
- Completion
- 2013-12-01
- First posted
- 2011-03-29
- Last updated
- 2011-03-29
Locations
1 site across 1 country: China
Source: ClinicalTrials.gov record NCT01324557. Inclusion in this directory is not an endorsement.