Clinical Trials Directory

Trials / Completed

CompletedNCT01309347

Evaluation of the Development of an Advanced, Conformable Prosthetic Socket, Study I

Status
Completed
Phase
Study type
Observational
Enrollment
6 (actual)
Sponsor
Infoscitex Corporation · Industry
Sex
All
Age
Healthy volunteers
Not accepted

Summary

The purpose of this study is obtain prosthetist's feedback on the novel conformable socket material developed by Infoscitex, and determine if it is a viable alternative to current prosthetic socket liners. During this task, the research team will travel to the prosthetists locations to have them evaluate the socket system by examining the material and providing their professional opinions and feedback with regard to comfort and fit for the amputee, its ease of use, and breathability.

Detailed description

Modern prosthetics have improved significantly with regards to control and functionality, but the fit of the residual limb within a prosthetic socket is a primary concern for many amputees. A poor fit can lead to skin irritation, tissue breakdown, and pain. The volume of the residual limb of an amputee changes throughout the course of a day and throughout the year. Volume fluctuation within the socket can lead to issues for the amputee, including decreased comfort, increased shear forces, increased pressure on bony prominences, as well as a poor gait pattern. An uncomfortable or non-performing socket/residual limb interface decreases user compliance with the prosthetic and therefore decreases the activity level of amputees who want to remain active in their civilian and military lives. The investigators are developing a multilayered socket that takes advantage of a novel braided material for strength and passive conformability with thin layers dedicated to wearer comfort. This new socket provides ultimate fit for improvement in the performance of the prosthesis. The socket adapts itself to the changing physical shape of the residual limb as the prosthesis is worn. The adaptation is a natural result of the material properties, so is done passively and in real time. The materials are lightweight, breathable, and ultrasound transparent, allowing the prosthetic to function in a variety of environments. This study will be undertaken to have six prosthetists evaluate the material, where they will be asked to complete a questionnaire and give their opinions regarding the material. This will inform design changes for the material.

Conditions

Timeline

Start date
2011-03-01
Primary completion
2011-04-01
Completion
2011-04-01
First posted
2011-03-07
Last updated
2012-03-02

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT01309347. Inclusion in this directory is not an endorsement.