Bronchoscopy and Electric Impedance Tomography (EIT) Pilot Study

Bronchoscopy and Electric Impedance Tomography to Investigate the Influence of Bronchoscopy on Pulmonary Regional Ventilation Measurements by Electric Impedance Tomography (EIT)

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
20 (estimated)
Sponsor
RWTH Aachen University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Impedance changes in lung ventilation are investigated in mechanically ventilated patients who routinely undergo bronchoscopy in intensive care medicine. Bronchoscopy is performed to suction secretions as well as to analyze the secretions to recognize inflammations and diseases. It is an essential intervention which causes changes in ventilation which remain for 1-2 hours. It is not completely investigated why these changes in ventilation remain for so long time and how they are distributed regionally. Therefore the purpose of this study is to investigate the change in pulmonary regional ventilation in patients who routinely undergo bronchoscopy to possibly generate ideas how to optimize the ventilation after bronchoscopy to optimize the patient´s treatment.

Detailed description

In 20 mechanically ventilated patients who routinely undergo bronchoscopy Electrical Impedance Tomography (EIT) measurements whereby, evaluable data of 10 patients are needed, of about 1-2 minutes are performed directly before, directly after and 10, 30, and 60 minutes after bronchoscopy parallel to the following routine measurements: tidal volume, resistance, compliance, heart rate, blood pressure, SpO2 and blood gas values. Prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax connected with an EIT- device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. The EIT provides a mapping of the distribution of the lung´s electrical impedance and exhibits a far temporal resolution of up to 40 tomograms per second. Because of electrical impedance of the pulmonal tissue is dependant to the air content, the air distribution within the lung over a certain period can be monitored. Analyzing the EIT- data it might be possible to explain the distribution in regional ventilation and how the ventilation could be optimized right after the bronchoscopy to optimize the patient´s treatment.

Conditions

Interventions

TypeNameDescription
DEVICEElectrical Impedance Tomography (EIT)EIT measurements of 1-2 minutes are performed in patients who routinely undergo bronchoscopy (during 1.5 hours) before, directly after and 10, 30, 60 minutes after bronchoscopy. Therefore the rubber belt including 16 integrated electrographic electrodes is placed around the patient´s chest and connected with an EIT device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. Pseudonomyzed EIT data are evaluated descriptively.

Timeline

Start date
2011-01-01
Primary completion
2011-04-01
Completion
2011-04-01
First posted
2011-02-14
Last updated
2011-02-16