Clinical Trials Directory

Trials / Unknown

UnknownNCT01286064

Colorectal Cancer Detection by Means of Optical Fluoroscopy

Role of Natural Fluorescence of Human Blood Plasma in Patients With Colorectal Cancer.

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
200 (estimated)
Sponsor
Fondazione IRCCS Istituto Nazionale dei Tumori, Milano · Academic / Other
Sex
All
Age
18 Years – 75 Years
Healthy volunteers
Accepted

Summary

The aim of the present prospective study was to investigate the fluorescence emission of human blood plasma of patients with colorectal cancer. For years, serum tumor markers have been studied for the diagnosis and follow-up of colorectal cancer, among which carcinoembryonic antigen (CEA) has achieved promising results. However, the sensitivity of CEA for colorectal cancer is less than 25% and elevated CEA levels also occur in patients with benign disease, as well as in patients with other carcinomas. Nevertheless, surveillance programs are often based on the CEA test and combination with other markers is at present a matter of research. Alternative methods based on optical fluoroscopy have been introduced in experimental stages for clinical diagnosis of cancer. Few studies have been reported on the application of native fluorescence spectroscopy of biofluids in the diagnosis of tumoral diseases. The above reported findings prompted us to investigate the fluorescence emission of human blood plasma of patients with colorectal cancer. For this purpose, the blood of patients was collected and the fluorescence Preliminary measurements on plasma of patients bearing colon cancer showed that the fluorescence spectra were mainly characterized by the presence of an emission peaking at 620-630 nm, whose excitation spectrum peaked at 405 nm. Hence, an excitation wavelength of 405 nm was selected for the study. The fluorescence emission spectra were recorded in the range of 430-700 nm.

Detailed description

Eligibility criteria: Gastrointestinal disease or clinical symptoms related to colorectal cancer risk submitted to endoscopy. Exclusion criteria consisted of age younger than 18 years, history of psychiatric illness, and preoperative radiotherapy. Outcome: investigated the possible role of the native fluorescence of blood plasma in the management of colorectal cancer (CRC) and its feasibility as a new tumor marker. Sample of blood was collected from asymptomatic blood donors and from CRC patients. The native fluorescence of blood plasma was measured using a conventional spectrofluorimeter.

Conditions

Interventions

TypeNameDescription
DEVICEOptical FluoroscopyLithium-heparin was added to the blood samples to prevent coagulation. The samples were then centrifuged and the plasma was removed without disturbing the buffy coat and the erythrocyte sediments. The separated changes in the enzyme associated with heme biosynthesis have been reported for peripheral mononuclear cells in patients with epithelial tumors and metastatic spread. plasma was stored at -20 °C until assayed. For fluorescence measurements, analytical grade acetone was added to plasma in a 1:1 ratio by volume and the mixture was centrifuged. The clear supernatant was placed in a quartz cuvette of 1 cm path length for further analysis. Fluorescence analysis of blood plasma was performed by means of a spectrofluorometer (Model F-3000, Hitachi, Ltd., Tokyo, Japan).
DEVICEOptical FluoroscopyLithium-heparin was added to the blood samples to prevent coagulation. The samples were then centrifuged and the plasma was removed without disturbing the buffy coat and the erythrocyte sediments. The separated changes in the enzyme associated with heme biosynthesis have been reported for peripheral mononuclear cells in patients with epithelial tumors and metastatic spread. plasma was stored at -20 °C until assayed. For fluorescence measurements, analytical grade acetone was added to plasma in a 1:1 ratio by volume and the mixture was centrifuged. The clear supernatant was placed in a quartz cuvette of 1 cm path length for further analysis. Fluorescence analysis of blood plasma was performed by means of a spectrofluorometer (Model F-3000, Hitachi, Ltd., Tokyo, Japan).

Timeline

Start date
2010-10-01
Primary completion
2010-12-01
Completion
2011-04-01
First posted
2011-01-31
Last updated
2011-01-31

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT01286064. Inclusion in this directory is not an endorsement.