Clinical Trials Directory

Trials / Completed

CompletedNCT01284244

A Randomized Controlled Trial of the Uresta Continence Pessary

A Randomized Controlled Trial of the Uresta Continence Pessary; Short-term Uresta Efficacy Study (SURE Study)

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
36 (actual)
Sponsor
Mount Sinai Hospital, Canada · Academic / Other
Sex
Female
Age
18 Years
Healthy volunteers
Not accepted

Summary

Stress urinary incontinence (SUI) is defined as the involuntary loss of urine with an increase in abdominal pressure, caused either by a loss of support under the bladder neck, or intrinsic urethral sphincter deficiency. It is a common problem in women that can significantly impact quality of life, with up to 30% developing SUI at some point in their lifetime. The most commonly utilized treatments for SUI include either pelvic floor (Kegel) exercises, or surgery. Many women find Kegel exercises unsatisfactory, but are reluctant to undergo a surgical procedure. Also, women who are poor candidates for surgery have limited options if Kegel exercises are unsuccessful. Over the years, there have been numerous attempts to develop effective non-surgical alternatives for treating SUI, but the results have been variable and the available data on efficacy limited. A new intravaginal incontinence pessary (Uresta) has been developed for treating stress incontinence, and is currently available in Canada via a medical distributor. The self-positioning device is initially fitted by a healthcare provider, but then can subsequently placed by the patient as needed. Uresta is designed to be easily inserted into the vagina and spontaneously fall into position, providing support beneath the urethra. A single, uncontrolled study of 21 women showed that Uresta significantly reduces urinary incontinence measures, with no reported complications. Using questionnaires, a 47% reduction in self-reported SUI symptoms was demonstrated. Pad weight following a pad test, an objective assessment of urine loss, showed a 50% reduction in leakage. This trial is intended to be a short-term assessment of the efficacy of the Uresta device, using a placebo arm in order to remove any of the possible sources of patient biases. The placebo ("sham") group will be obtained by placing a flexible silastic ring (inactivated Estring) high in the vagina where it will not alter urethral forces. The aim is to unequivocally determine whether the Uresta device provides the necessary urethral support to stop urine leakage from stress incontinence. The hypothesis is that the Uresta device will significantly reduce urinary losses from baseline, shown as a significant reduction pad weight following a pad test with the device in place.

Conditions

Interventions

TypeNameDescription
DEVICEUresta pessaryParticipants randomized to the Uresta group will be fitted with device before immediately before performing the pad test. The Uresta pessary is made of medical grade rubber that has been extensively tested for safety. It is bell-shaped, with a narrow tip that allows for easy insertion into the vagina in a similar fashion to a tampon. The device can be easily inserted, and removed by a patient for use when needed. The Uresta comes in 3 sizes. Fitting starts with insertion of the smallest size. If urine leakage continues with valsalva or a cough stress test, it can be replaced by one size larger, until leakage is stopped. If the device prevents the patient from being able to void or is uncomfortable due to its size, the smaller size is replaced. Following the pad test, the participant will be given the opportunity to keep the device for continued use, or remove it if desired.
DEVICESilastic ringThe silastic ring is a plastic flexible ring similar to that used to administer vaginal estrogen (Estring). It is well tolerated and would not contain any medications. Immediately before performing the pad test, it would be placed high in the vagina, away from the urethra. It would be removed immediately after the pad test. Draping will conceal from the patient which device was inserted.

Timeline

Start date
2011-01-01
Primary completion
2013-12-01
Completion
2014-05-01
First posted
2011-01-26
Last updated
2017-03-31
Results posted
2017-03-31

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT01284244. Inclusion in this directory is not an endorsement.