Clinical Trials Directory

Trials / Unknown

UnknownNCT01193465

Temperature and Humidity Among Different Anesthesia Work-station

Comparison of Heat and Humidity Conservation Among Different Anesthesia Workstation and Different Flow Rate.

Status
Unknown
Phase
Phase 4
Study type
Interventional
Enrollment
60 (estimated)
Sponsor
Korea University Anam Hospital · Academic / Other
Sex
All
Age
18 Years – 70 Years
Healthy volunteers
Not accepted

Summary

The effects of preserving humidity and temperature by low flow anesthesia are different in each other anesthesia workstation.

Detailed description

The fresh gas flow(FGF) is dry and cold in old fashioned anesthesia machine, especially at high folw (above 1 L/min). To the contrary, it has been assumed that the heat and humidity of FGF may be preserved using low FGF (below 1 L/min) during anesthesia or new anesthesia work station. However, it has not been proved yet. We hypothesized that the heat and moisture of FGF may be different in various FGF rate during anesthesia. In addition, it may be different in accordance to anesthesia work station. Therefore, we planed prospective observational study that will demonstrate that the difference of heat and moisture of FGF in different anesthesia work station (Excel; 1st generation anesthesia machine of Datex-Ohmeda Corp., Avance; 2nd generation anesthesia work station of Datex-Ohmeda Corp., Cato; 2nd generation generation anesthesia work station of Drager, Primus; 3rd generation generation anesthesia work station of Drager) and different FGF (0.5, 1, 4 L/min)

Conditions

Interventions

TypeNameDescription
DEVICEDatex Ohmeda excel anesthesia machinemaintain one of following fresh gas flow, 1 or 4 L/min (nitrous oxide:oxygen =1:1) during 2 hour with using Datex Ohmeda excel anesthesia machine after draping complete
DEVICEDatex Ohmeda Avance anesthesia work-stationmaintain one of following fresh gas flow, 0.5 or 1 or 4 L/min (nitrous oxide:oxygen =1:1) during 2 hour with using Datex Ohmeda Avance anesthesia machine after draping complete
DEVICEDrager Cato anesthesia work-stationmaintain one of following fresh gas flow, 0.5 or 1 or 4 L/min (nitrous oxide:oxygen =1:1) during 2 hour with using Drager Cato anesthesia work-station after draping complete
DEVICEDrager Primus anesthesia work-stationmaintain one of following fresh gas flow, 0.5 or 1 or 4 L/min (nitrous oxide:oxygen =1:1) during 2 hour with using Drager Primus anesthesia work-station after draping complete

Timeline

Start date
2010-01-01
Primary completion
2010-09-01
Completion
2010-10-01
First posted
2010-09-02
Last updated
2010-09-02

Locations

1 site across 1 country: South Korea

Source: ClinicalTrials.gov record NCT01193465. Inclusion in this directory is not an endorsement.