Trials / Completed
CompletedNCT01180439
Patient-Ventilator Interactions in Chronic Obstructive Pulmonary Diseases (COPD) Under Non-Invasive Ventilation
Patient-Ventilator Interactions During Sleep Under Non-Invasive Ventilation in Severe Stable COPD
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 8 (actual)
- Sponsor
- Ligue Pulmonaire Genevoise · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Non-invasive ventilation (NIV) in severe hypercapnic Chronic Obstructive Pulmonary Diseases (COPD) may be associated - during sleep - with recurrent episodes of patient ventilatory asynchrony, which in turn may affect quality of sleep, efficacy of ventilation and comfort of nocturnal NIV.Polysomnography (PSG) under NIV is necessary to detect these events. Adjusting ventilator settings according to respiratory events detected by PSG with NIV may improve quality of sleep, efficacy of ventilation and comfort of nocturnal NIV.
Detailed description
Patients under NIV for hypercapnic COPD have several reasons to develop patient-ventilatory asynchrony: delayed cycling, and insufficient expiratory time may induce progressive dynamic hyperinflation, and increase intrinsic positive end-expiratory pressure (PEEPi); too high levels of pressure support may also contribute to dynamic hyperinflation. Increase in PEEPi is associated with two respiratory events: unrewarded inspiratory efforts, and auto-triggering. Our hypotheses are: 1/that these events occur frequently in COPD under NIV and that they are not detected by medical history or usual monitoring tools (SpO2; PtcCO2); 2/ that they can be easily detected by polysomnography; 3/ that simple adjustments of ventilator parameters aiming to reduce dynamic hyperinflation and unrewarded inspiratory efforts may improve efficacy of ventilation, quality of sleep and comfort of treatment. The present study compares the results of two consecutive sleep studies: 1.PSG under NIV in severe stable COPD under "usual ventilator settings" with 2.PSG under NIV after adapting ventilator settings to results of initial PSG.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Adjustment of ventilator settings (device) | Decrease in pressure support, increase in respiratory back-up rate, increase in expiratory positive airway pressure (EPAP) to counteract effect of PEEPi, and adjustment of cycling (at higher percentage of peak inspiratory flow) |
Timeline
- Start date
- 2009-10-01
- Primary completion
- 2010-08-01
- Completion
- 2010-08-01
- First posted
- 2010-08-12
- Last updated
- 2010-08-12
Locations
1 site across 1 country: Switzerland
Source: ClinicalTrials.gov record NCT01180439. Inclusion in this directory is not an endorsement.