MD Logic Pump Advisor- Adults Study

Evaluation of Automated Insulin Pump Settings Using the MD-Logic Pump Advisor-Adults Sub Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
18 (actual)
Sponsor
Rabin Medical Center · Academic / Other
Sex
All
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

Prospective, randomized, controlled, 30-78 days trial comparing MD-Logic pump algorithm to the standard of care of patients with type 1 diabetes. The objective of this feasibility study is to evaluate the efficacy and safety of automated determined Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) using the MD-Logic Pump Advisor in individuals with type 1 diabetes.The study will be consisted from two segments:(I)pilot study, 30-78 days trial evaluating the MD-Logic pump advisor and (II)randomized controlled 30-78 days trial comparing MD-Logic pump algorithm to the standard of care.In segment 1, the pilot study, the aim is to enroll 15-30 subjects without control group. In segment 2, the randomized controlled segment, the aim is to enroll 92 subjects, but enrolling up to 105 eligible subjects to allow for dropouts. The randomized controled study segment will be initiated after the pilot segment.Each segment of the study will consist of 6 clinic visits taking place at intervals of 1-3 weeks, sum of 30-78 days study duration for each segment. Before each clinic visit, subjects will wear continuous glucose sensors for 6 days; the intervention group will have up to 4 iterations (e.g the pump setting will be reviewed and adjusted up to 4 times during the study period according to the MD-Logic Pump Advisor).For the control group (at segment 2 only), insulin pump settings will not be changed during the study period (patient's usual standard of care).

Detailed description

the MD-Logic Pump Advisor was design by the Diabetes Technology Center, the Institute of Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel. The MD-Logic Pump Advisor learns and adapts the patient's insulin pump settings in order to optimize glucose control. The MD-Logic Pump Advisor needs, as input, sensor readings, insulin delivery and recording of the meals during home care. During collection of the data, the patients are asked to continue their daily routine (no need for special consideration). The present study was designed to test the automatic algorithm that will evaluate and change, when necessary, the patient's insulin pump settings based on prior sensor reading, insulin delivery, and meals data that was collected while the patient is under his regular treatment at home. The objective of this feasibility study is to evaluate the efficacy and safety of automated determined Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) using the MD-Logic Pump Advisor in individuals with type 1 diabetes. The study will be consisted from two segments:(I)pilot study, 30-78 days trial evaluating the MD-Logic pump advisor and (II)randomized controlled 30-78 days trial comparing MD-Logic pump algorithm to the standard of care.In segment 1, the pilot study, the aim is to enroll 15-30 subjects without control group. In segment 2, the randomized controlled segment, the aim is to enroll 92 subjects, but enrolling up to 105 eligible subjects to allow for dropouts. The randomized controled study segment will be initiated after the pilot segment.Each segment of the study will consist of 6 clinic visits taking place at intervals of 1-3 weeks, sum of 30-78 days study duration for each segment. Before each clinic visit, subjects will wear continuous glucose sensors for 6 days; the intervention group will have up to 4 iterations (e.g the pump setting will be reviewed and adjusted up to 4 times during the study period according to the MD-Logic Pump Advisor).For the control group (at segment 2 only), insulin pump settings will not be changed during the study period (patient's usual standard of care). Endpoints: * Primary endpoint Increase in time spent in the normal range, defined as sensor glucose level within 70 to 180 mg/dl * Secondary endpoints Reduced time spent above 180 mg/dl, reduced time spent below 70 mg/dl, reduced number of hypoglycemic events below 63 mg/dl, reduced glucose variability, quality of life measurements and subject treatment satisfaction. Inclusion Criteria: * Subject with Type 1 diabetes (\>1yr since diagnosis) * Medtronic ( MiniMed Paradigm 522, 512 , 722 or 712) insulin infusion pump CSII (continuous subcutaneous insulin infusion) therapy for at least 3 months * Age ≥ 18 years * HbA1c at inclusion ≥ 6.0% * No concomitant diseases that influence metabolic control * No current use of CGM * Subjects do not participate in any other interventional study

Conditions

Interventions

TypeNameDescription
DEVICEMD Logic Pump AdvisorInsulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) will be adjusted using the MD-Logic Pump Advisor