Trials / Unknown
UnknownNCT01133925
Optical Coherence Tomography in Long Lesions
Optical Coherence Tomography in Long Native Coronary Artery Lesions Treated With Multiple Novel Zotarolimus-eluting Stents: LONG OCT STUDY
- Status
- Unknown
- Phase
- Phase 4
- Study type
- Interventional
- Enrollment
- 22 (actual)
- Sponsor
- A.O. Ospedale Papa Giovanni XXIII · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
Increasing lesion complexity in percutaneous coronary interventions (PCI) has warranted the use of overlapping drug-eluting stents. Whether the substantial impairment of arterial healing observed at sites of overlap in preclinical pathologic studies persists in patients undergoing PCI is unknown. Consecutive patients with long lesions in native coronary vessels requiring stents in overlap are prospectively assigned to receive multiple zotarolimus eluting stents (Resolute Sprint). The completeness of stent struts coverage and/or late malapposition are evaluated by Optical Coherence Tomography at 6 months follow-up.Data will be compared to the historical arm of ODESSA trial (patients treated with multiple sirolimus-,paclitaxel polymer-or zotarolimus eluting stents).
Detailed description
It is not unknown whether overlapping drug-eluting stents provide increased vessel toxicity. Given the association of delayed healing and incomplete endothelialization observed in animal and human autopsy studies at overlapping sites it is unclear why most patients do well with multiple DES implanted. OCT detects smaller degrees of in-stent neointima more accurately than IVUS and might be a useful method for identify strut coverage and/or malapposition. Patients if eligible on the basis of clinical and angiographic criteria, are assigned to receive multiple Resolute Sprint™. Stent implantation are done accordingly to the normal interventional practice. QCA and IVUS are performed at the end of optimal stents placement per visual judgement (residual stenosis \< 10%, TIMI 3 flow). Stent, lumen size and volume as well as complete stent strut apposal will be determined by IVUS analysis. Clinical follow-up will take place at 1 month (±1 week), 6 months (±2 weeks) and 1 year (±2 weeks). At 6-months follow-up all patients will undergo a quantitative coronary angiography (QCA), IVUS and Optical Coherence Tomography (LightLab OCT Imaging M2, automated pull back and flushing combination)assessments. OCT images will be acquired at 15-30 frames per second. Blind corelab quantitative strut by strut analysis will be performed using a novel dedicated software at each 0.5 mm section. The following OCT variables will be evaluated:number of visualized strut per section, mean-max neointimal thickness per section, % struts well apposed with neointima at overlapping vs non overlapping sites, % struts without neointima, % struts malapposed, rate of \> 30% uncovered struts/total number of struts per section. Obtained data will be compared with the data from a historical comparator (ODESSA trial that presented results from TAXUS Libertè™ vs Cypher Select™ vs Endeavor™ stents implanted in overlap to treat long lesions.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | Resolute Sprint | Zotarolimus Eluting Stent (Resolute Sprint) implanted in overlap |
| DEVICE | Sirolimus Eluting Stent | Cypher stents implanted in overlap |
| DEVICE | Paclitaxel Eluting Stent | Taxus stents implanted in overlap |
| DEVICE | Zotarolimus eluting stent | Endeavor stents implanted in overlap |
Timeline
- Start date
- 2008-05-01
- Primary completion
- 2009-08-01
- Completion
- 2011-05-01
- First posted
- 2010-05-31
- Last updated
- 2010-05-31
Locations
1 site across 1 country: Italy
Source: ClinicalTrials.gov record NCT01133925. Inclusion in this directory is not an endorsement.