Clinical Trials Directory

Trials / Completed

CompletedNCT01133652

Variation In Success of Intravenous (IV) Placement With Observation Using New Techniques

The VISION STUDY: Variation In Success of Intravenous (IV) Placement With Observation Using New Techniques

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
399 (actual)
Sponsor
University of Alberta · Academic / Other
Sex
All
Age
1 Day – 16 Years
Healthy volunteers
Not accepted

Summary

Children fear having an intravenous (IV) needle placed because of the pain that they will experience. The more needle punctures that a child has to endure before the IV is successfully placed, the greater the pain experienced and anxiety suffered. In addition, false starts increase the demands on medical staff and can increase the length of the emergency department stay. Often, veins are difficult to see or feel, particularly in an unwell, dehydrated child or in young infants who have more fat below the skin surface. Also, the venous pattern below the skin surface naturally varies from person to person and therefore success in placing IVs leaves room for improvement. Technology may be able to play an important role is improving the rates of success. The investigators wish to investigate whether the use of either an Ultrasound machine or a VeinViewer machine can improve the rate of success of the initial attempt (skin puncture) at peripheral IV placement in comparison to the current standard approach.

Detailed description

Peripheral IV line placement is one of the most common and challenging painful procedures performed in the pediatric emergency department (PED). The lack of a clear visual guide for IV placement often leads to multiple painful attempts; delays in urgent treatment; increased use of human resources; increased costs; and increased anxiety in the patient, the parents and the staff. The research plan is a randomized controlled trial (RCT) to compare the use of two new technologies with the current standard method for vein location and IV placement in children.We would like to know if either of these technologies improve rates of successful IV placement on first attempt. Furthermore we would like to know if either technology leads to decreased time spent by staff on the procedure or decreased overall number of painful attempts. Information on nursing satisfaction, parental satisfaction and cost analysis will also be obtained.

Conditions

Interventions

TypeNameDescription
DEVICEVeinviewerVeinviewer machine
DEVICEUltrasoundUltrasound
OTHERConventional techniqueConventional IV placement by nurses

Timeline

Start date
2010-05-01
Primary completion
2012-08-01
Completion
2012-08-01
First posted
2010-05-31
Last updated
2012-08-24

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT01133652. Inclusion in this directory is not an endorsement.