Trials / Completed
CompletedNCT01124942
MGuard Stent in ST-elevation Myocardial Infarction
MGuard vs bAre-metal Stents Plus Manual Thrombectomy in Real World STEMI Patients: a Prospective Multicenter Randomized Trial
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 350 (actual)
- Sponsor
- Federico II University · Academic / Other
- Sex
- All
- Age
- 18 Years
- Healthy volunteers
- Not accepted
Summary
The Investigators will test the hypothesis that MGuard net protective stent, the investigational device, would be superior to conventional revascularization strategy (i.e. bare-metal stenting plus manual thrombectomy), for STEMI patients undergoing urgent percutaneous coronary interventions.
Detailed description
Embolization of thrombotic debris still represents a complication for ST-elevation myocardial infarction (STEMI) patients undergoing percutaneous coronary interventions (PCI). Distal embolization may decrease coronary and myocardial reperfusion after PCI in STEMI setting. Unfortunately, intracoronary filters present several important limitations limiting their use and their efficacy especially in presence of huge amount of thrombus. In this respect, recent trials investigated whether a default manual thrombectomy strategy before stenting would ameliorate angiographic as well as clinical outcomes for STEMI patients undergoing percutaneous revascularization. Of note, the most of embolization occurs when guidewire, and thrombectomy device cross the thrombus, and after the stent has been implanted as a consequence of plaque prolapse through the stent struts. MGuard net protective stent, the investigational device, is a bare-metal stent covered with a ultra-thin flexible polyethylene terephthalate (or Dacron) mesh sleeve, that is anchored to the external surface of the struts. This biocompatible fiber net (string diameter 10-22 μm) has minimal effects on the stents' trackability and deliverability. During stent deployment, the net stretches and slides over the expanding stent struts, trapping the thromboembolic debris underneath the fiber net and isolating the prothrombotic intima components from the blood stream. This protocol will test the hypothesis that MGuard stent would be superior to conventional revascularization strategy (i.e. bare-metal stenting plus manual thrombectomy), for STEMI patients undergoing urgent PCI in terms of angiographic as well as clinical outcomes.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | MGuard net protective coronary stent | It is a new closed-cell design stent concept. with an ultra-thin flexible polyethylene terephthalate (or Dacron) mesh sleeve, anchored to the external surface of the struts. This net (string diameter 10-22 μm) minimally affects stents' trackability and deliverability. During stent deployment, the net stretches and slides over the expanding stent struts, trapping the thromboembolic debris underneath the fiber net. |
| DEVICE | Bare-metal stent and manual thrombectomy device | Manual thrombectomy device as an adjunctive strategy for conventional stenting with a bare-metal stent |
Timeline
- Start date
- 2010-03-01
- Primary completion
- 2011-03-01
- Completion
- 2013-03-01
- First posted
- 2010-05-18
- Last updated
- 2022-03-31
Locations
1 site across 1 country: Italy
Source: ClinicalTrials.gov record NCT01124942. Inclusion in this directory is not an endorsement.