Clinical Trials Directory

Trials / Completed

CompletedNCT01113255

Validation of a Simulated Clinical Evaluation of Ventilators

Status
Completed
Phase
Phase 2 / Phase 3
Study type
Interventional
Enrollment
54 (actual)
Sponsor
Assistance Publique - Hôpitaux de Paris · Academic / Other
Sex
All
Age
6 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to evaluate the ability of a device reproducing patients' respiratory characteristics to select in-VITRO the most appropriate ventilator for a given pathology.

Detailed description

Context : Mechanical ventilation is an essential element in the management of chronic as well as acute respiratory failure allowing an improvement of both mortality and morbidity. However, considering the wide choice of ventilators available on the market, it has become increasingly difficult to choose the most appropriate ventilator according to the pathology presented by a patient, patients being able to try only a limited number of devices. Patient-ventilator synchronization is a crucial part of ventilation efficacy and its success. It depends on both the physiopathological characteristics of patients and specific properties of the ventilation device. Objective : To evaluate the ability of a device reproducing patients' respiratory characteristics to select in-VITRO the most appropriate ventilator for a given pathology. Method : Multi-center transversal study. Selection, after an initial bench-evaluation, of three ventilators. Clinical evaluation of their efficacy and synchronization between patient and ventilator and establishment of a classification. Second bench evaluation of the studied ventilators while the bench is simulating the ventilation characteristic of previously studied patients in order to compare the results obtained in VITRO to the results obtained in vivo. Selection criteria : Patients requiring mechanical ventilation for management of either chronic or acute respiratory failure. Patients, centers : 4 groups of 14 patients presenting chronic respiratory disease followed in the ICU of RAYMOND POINCARE HOSPITAL in GARCHES and in the pulmonary departments of the Armand Trousseau hospital and the PITIE SALPETRIERE IN PARIS; 1 cohort of 12 patients admitted in the ICU of Henri Mondor in CRETEIL IN PARIS for acute respiratory failure. Study duration : 33 months (bench study : 3 + 6 months, clinical study : 24 months) Perspectives : Developing an evaluation tool allowing the rapid assessment of any new available ventilator according to the specific characteristics (and needs) of a patient and to a given pathology. Selecting the most appropriate ventilator for a given patient.

Conditions

Interventions

TypeNameDescription
PROCEDUREbench-evaluation, of three ventilatorsto select in-VITRO the most appropriate ventilator for a given pathology.

Timeline

Start date
2009-03-01
Primary completion
2011-09-01
Completion
2011-12-01
First posted
2010-04-29
Last updated
2014-11-06

Locations

1 site across 1 country: France

Source: ClinicalTrials.gov record NCT01113255. Inclusion in this directory is not an endorsement.