Clinical Trials Directory

Trials / Completed

CompletedNCT01012960

Opioids and Esophageal Function

Is the Opioid-induced Pharyngeal and Esophageal Dysfunction Peripherally or Central Mediated?

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
13 (actual)
Sponsor
Region Örebro County · Academic / Other
Sex
All
Age
18 Years – 40 Years
Healthy volunteers
Accepted

Summary

The purpose of this study is to evaluate if opioid-induced effects on the pharynx and esophagus is centrally or peripherally mediated.

Detailed description

Opioids induce pharyngeal and esophageal dysfunction and reduce the lower esophageal sphincter (LES) pressure, and thereby decreases the barrier pressure between the stomach and esophagus. This contributes to an increased risk of regurgitation and aspiration during anaesthesia induction and in the postoperative period, when the patient is treated with opioids for pain relief. The effects of opioid antagonists on the opioid induced pharyngeal dysfunction and lower esophageal sphincter pressure are unknown. Therefore it is of great clinical value to evaluate if these negative effects are reversed by peripheral opioid antagonist, methylnaltrexone. Methylnaltrexone is one of the newer agents of peripherally acting opioid antagonists that act to reverse some of the side effects of opioid drugs, such as constipation, without affecting analgesia. If the opioid induced pharyngeal and esophageal dysfunction and reduction of the lower esophageal sphincter pressure is peripherally induced or mediated via peripheral opioid receptors, methylnaltrexone might reverse these effects and thereby reduce postoperative morbidity by reducing pulmonary complications. On the other hand, if the dysfunction is centrally induced and not mediated via peripheral opioid receptors there is no effect of methylnaltrexone. The pharyngeal and esophageal motility/function can be registered in an easy and objective way with the high resolution manometry, ManoScan 360. ManoScan 360 is an equipment with 36 sensors at 1 cm spacing with 12 tip transducers at every sensor. The 36 closely spaced sensors automatically capture all relevant motor function from the pharynx to the stomach. The system collects reliable and consistent data records with improved diagnostic accuracy, and the data are analyzed using ManoView analyzes software. ManoScan 360 has a CE mark approval and has been used at Örebro University Hospital during the last two years.

Conditions

Interventions

TypeNameDescription
DRUGmethylnaltrexone0,15 mg/kg sc ( subcutaneously)once per volunteer

Timeline

Start date
2009-11-01
Primary completion
2010-01-01
Completion
2010-01-01
First posted
2009-11-13
Last updated
2011-12-09

Locations

2 sites across 1 country: Sweden

Source: ClinicalTrials.gov record NCT01012960. Inclusion in this directory is not an endorsement.