Clinical Trials Directory

Trials / Completed

CompletedNCT01005264

Removable Walker for Neuropathic Ulcers

Effectiveness of Removable Walker Cast Versus Non-removable Fiberglass Off-bearing Cast in the Healing of Diabetic Plantar Foot Ulcer- a Randomized Controlled Trial

Status
Completed
Phase
Phase 3
Study type
Interventional
Enrollment
48 (actual)
Sponsor
IRCCS Multimedica · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Not accepted

Summary

1. Objective: To evaluate the efficacy of removable cast walker compared to non-removable fiberglass off-bearing cast in the treatment of diabetic plantar foot ulcer 2. Research design and methods: Forty-five adult diabetic patients with non-ischemic, non-infected neuropathic plantar ulcer were randomized to treatment with a non-removable fiberglass off-bearing cast (TCC group) or walker cast (Stabil-D group). Treatment duration was 90 days. Percent reduction in ulcer surface area and total healing rates were evaluated after treatment.

Detailed description

Study design: Two centers specializing in diabetic foot management (located in Sesto S. Giovanni and Milan, Italy) participated to this open, randomized clinical trial. The ethics-committee approved the study on January 10th, 2008. Enrollment of consecutive patients began February 2008 and ended March 2009. Eligible patients were fully informed of the study aim and procedures and written consent was obtained prior to study participation. Patients were then randomly assigned to one of the two treatment groups by opening randomization codebreak envelopes containing one of the two options. Separate randomization was performed for each center, and a copy of all randomization envelopes was kept at the statistical department of the Multimedica center. The two arms were composed of patients managed with non-removable fiberglass off-bearing cast (TCC group) and patients offloaded with the Stabil-D® (Podartis srl, Montebelluna, Treviso, Italy) walker cast (Stabil-D group).

Conditions

Interventions

TypeNameDescription
DEVICEnon-removable fiberglassTwo types of fiberglass bandages (Softcast3M®, 3M Health Care, St. Paul, MN (USA)) were used for construction of the pressure-relief apparatus
DEVICEStabil-D®Stabil-D Stabil-D® is composed of a specifically designed rigid, boat shaped, and rocker sole

Timeline

Start date
2008-02-01
Primary completion
2009-03-01
Completion
2009-03-01
First posted
2009-10-30
Last updated
2009-10-30

Locations

1 site across 1 country: Italy

Source: ClinicalTrials.gov record NCT01005264. Inclusion in this directory is not an endorsement.

Removable Walker for Neuropathic Ulcers (NCT01005264) · Clinical Trials Directory