Clinical Trials Directory

Trials / Completed

CompletedNCT00980889

RCT Steel (Wallstent®) vs Nitinol (Wallflex®) Bile Duct Stent for Palliation of Malignant Obstruction

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
400 (actual)
Sponsor
Stockholm South General Hospital · Academic / Other
Sex
All
Age
20 Years
Healthy volunteers
Not accepted

Summary

Less than 20% of patients with malignant distal bile duct (BD) obstruction (often pancreatic cancer) are suitable for resection surgery.In the rest,palliation treatment comes into focus. Jaundice caused by BD obstruction gives pain, infection (cholangitis), often itching and increased weight loss, and the patient is stigmatized by the deep yellow colour of the skin.Therefore palliation with endoscopic stenting by ERCP-technique is important. Modern self-expanding metal stents (SEMS) are now widely used in this context. Comparison in a RCT between steel and nitinol SEMS has never been performed. The steel stent (Wallstent®) is the "original",is widely used, and has more expanding power. Nitinol stents are softer and claimed to be easier to insert,and are more and more popular.A newly developed nitinol stent (Wallflex®)may have these advantages, but is some 120 Euros more expensive. Regarding the most important outcome measure, time to stent failure (obstruction), no one knows if there is any difference.Our hypothesis is that there is no difference in this main outcome endpoint.

Detailed description

Secondary outcome measures (compare above) are complications caused by the stent or stent insertion and technical ease to insert the stent. To discover a 12% difference between the 2 groups, regarding patency, 400 patients must be included in the trial, alfa 0.05, beta 0.8. Investigators know from previous trials (Single center trial South Hospital GIE 2006;63:986-995 and a newly finished similar swedish multicenter trial,prel data DDW- 09)that the 9 hospitals recruited will be able to include this no of patients in approximately 2.5 years. Investigators will have a shortest follow-up period of 10 months, followup will be by phone with standard questions connected to stent failure, which is defined clinically AND by a new ERCP with intervention because of an obstructed stent.

Conditions

Interventions

TypeNameDescription
DEVICESteelERCP procedure insertion of Metalic Steel Stent, Wallstent®
DEVICENitinolInsertion of Metalic nitinol Stent, Wallflex® in malignant distal bile duct obstruction

Timeline

Start date
2009-05-01
Primary completion
2012-06-01
Completion
2013-05-01
First posted
2009-09-21
Last updated
2014-04-08

Locations

11 sites across 1 country: Sweden

Source: ClinicalTrials.gov record NCT00980889. Inclusion in this directory is not an endorsement.