Clinical Trials Directory

Trials / Unknown

UnknownNCT00958178

A Novel Method of Preoxygenation Using a Bain Circuit

A Novel Method of Preoxygenation Using Partial Rebreathing Via a Coaxial Mapleson D Breathing System (Bain Circuit)

Status
Unknown
Phase
Phase 4
Study type
Interventional
Enrollment
40 (estimated)
Sponsor
National Health Service, United Kingdom · Other Government
Sex
Male
Age
18 Years – 40 Years
Healthy volunteers
Accepted

Summary

The purpose of this study is to determine whether rebreathing for a short time (a bit like breathing into a paper bag) will stimulate faster breathing and thus make the giving of Oxygen more effective. The hypothesis is that the investigators method (rebreathing) will be faster than the current method of administering Oxygen.

Detailed description

It is standard practice for patients to breathe oxygen before receiving a general anaesthetic. This is called preoxygenation. It is done by using a mask which fits snugly onto the face. But for how long should patients breathe oxygen? Is taking deep breaths a good idea? What is the best oxygen flow rate? These questions are important because preoxygenation is one of the things which makes anaesthesia safe, so finding the best way of doing it might help save lives. Previous research has attempted to identify the best way to give oxygen before anaesthesia. It seems that breathing pure oxygen for three minutes is enough, or if you are in an urgent situation, then taking deep breaths of pure oxygen for a minute will do. However, there is another possible way of doing it which has not yet been looked at. Asking someone to breathe back in the air they have just exhaled seems, on the face of it, to be pointless at best. But doing just that for a very short time will make the person breathe harder. Then when you give them pure oxygen, they will breathe it in really deeply and this might make the preoxygenation quicker. That's the theory. To test it we plan to ask 40 healthy people to do the standard preoxygenation, then try our new way. We won't be giving anaesthetic, just the oxygen. The hypothesis is that our new method will be quicker than the existing one.

Conditions

Interventions

TypeNameDescription
DRUGOxygenExperimental: Low flow Oxygen for 30 seconds then high flow for 3.5 minutes. Active comparator: High flow Oxygen for 4 minutes.

Timeline

Start date
2009-08-01
Primary completion
2010-06-01
Completion
2010-06-01
First posted
2009-08-13
Last updated
2009-08-13

Locations

1 site across 1 country: United Kingdom

Source: ClinicalTrials.gov record NCT00958178. Inclusion in this directory is not an endorsement.