Clinical Trials Directory

Trials / Completed

CompletedNCT00901485

Autotitrating Versus Standard Non-invasive Ventilation (NIV) in Newly Diagnosed Patients

Autotitrating Non-invasive Ventilation (NIV) Versus Standard NIV; a Randomised Crossover Trial in Patients With Newly Diagnosed Hypoventilation

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
23 (actual)
Sponsor
ResMed · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The aim of the study is to compare the efficacy and tolerance of autotitrating non-invasive ventilation (NIV) versus standard NIV in patients with newly diagnosed nocturnal hypoventilation who have never experienced nocturnal, home NIV.

Detailed description

The aim of the study is to compare the effect of two types of noninvasive ventilator (a small machine that assists breathing) in patients newly diagnosed with nocturnal hypoventilation who are inexperienced in the use of noninvasive ventilation (NIV). NIV is standard therapy for patients with nocturnal hypoventilation. The most common type of NIV is bilevel pressure support which assists patient breathing by delivering different levels of air pressure during inspiration and expiration via a mask covering the nose or nose and mouth. Standard bilevel NIV (VPAP™) has been further developed to create a new automatically adjusting NIV (AutoVPAP™). Automatically adjusting NIV varies the inspiratory air pressure according to the airflow rates generated by the patient. This may improve patient comfort, hours of NIV use and recovery time. Patients over the age of 18 referred to, or under follow up at, the Royal Brompton Hospital who require domiciliary NIV but are inexperienced with use of NIV will be considered for entry into this randomised crossover study. If eligible for inclusion and willing to take part patients will be setup on automatically adjusting NIV or standard NIV, assigned in random order. At the end of one month the patient will be swapped to the alternative NIV for a further one month of domiciliary NIV treatment. At the end of each one month treatment period the patient will undergo overnight polysomnography, transcutaneous CO2 monitoring and 24 hour Holter monitoring.

Conditions

Interventions

TypeNameDescription
DEVICEAutoVPAPAutomatically titrated non-invasive ventilator, with target gross alveolar ventilation and back up respiratory rate determined by learn function. Nocturnal use for one month in patient's home.
DEVICEVPAPIIIST-AStandard non-invasive ventilator with pressure and respiratory rate settings determined by healthcare professional. Nocturnal use for one month in the patient's home.

Timeline

Start date
2009-04-01
Primary completion
2011-03-01
Completion
2011-03-01
First posted
2009-05-13
Last updated
2021-06-18
Results posted
2021-06-18

Locations

1 site across 1 country: United Kingdom

Source: ClinicalTrials.gov record NCT00901485. Inclusion in this directory is not an endorsement.