Trials / Unknown
UnknownNCT00865813
Biopsy Incisional With Trepan in Periocular Lesions
- Status
- Unknown
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 40 (estimated)
- Sponsor
- University of Sao Paulo · Academic / Other
- Sex
- All
- Age
- —
- Healthy volunteers
- Accepted
Summary
The purpose of this study was to identify accuracy rates of 2mm punch biopsy technique in diagnosing periocular malignancy.
Detailed description
In each case, the histology obtained at biopsy was compared with that identified at the time of tumor excision.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | Punch Biopsy | 1. Instillation of anesthetic eye drops. 2. Asepsis 3. Placement of surgical cloths and drapes 4. Infiltration of the involved region with anesthetic solution plus adrenalin in1:200.00 dilution. 5. Trephination of the most typical area of the lesion with a punch (2mm in diameter) of stainless steel by applying gentle pressure and twisting the trephine until its introduction into the suspicious lesions 6. Removal of the excised tissue with the aid of an insulin needle or conjuntival forceps, the base then bein cut with an number 11 surgical blade |
Timeline
- Start date
- 2008-12-01
- Primary completion
- 2009-10-01
- Completion
- 2009-12-01
- First posted
- 2009-03-19
- Last updated
- 2009-03-19