Clinical Trials Directory

Trials / Terminated

TerminatedNCT00749671

Bispectral Index Monitoring During Testing in the Electrophysiology Lab

To Assess the Utility of BIS Monitoring in the Administration of Moderate Sedation in Patients Undergoing Implantable Cardioverter -Defibrillator (ICD) Implantation With Defibrillatory Threshold (DFT) Testing

Status
Terminated
Phase
N/A
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Baystate Medical Center · Academic / Other
Sex
All
Age
21 Years – 65 Years
Healthy volunteers
Not accepted

Summary

BACKGROUND Physician-guided moderate sedation, administered by a Registered Nurse has been the standard of practice for patients undergoing a wide range of electrophysiology procedures during the past decade. Currently a subjective sedation assessment tool is the standard of practice within the Electrophysiology Lab (EP Lab). Bispectral Index monitoring (BIS) is an objective measure of the depth of sedation presently employed at Baystate Medical Center in the Intensive Care Unit and within the department of anesthesia. AIM The aim of this research study is to assess the utility of BIS monitoring in measuring the depth of sedation in patients undergoing defibrillation threshold testing (DFT). Our primary endpoint is: A change in OAAS scores of one point at the 30 minute data collection time period. Our secondary endpoints are: Lack of explicit recall of DFT testing and measurement of perioperative level of comfort. STUDY DESIGN AND SCOPE The population to be studied is those patients receiving a primary ICD implant or an ICD battery change with defibrillation threshold testing (DFT). All patients who have consented for ICD placement and DFT testing with moderate sedation will be invited to participate in this research study. Patients who are not candidates for DFT testing, as is determined by the EP physician, will be excluded from the study. Demographic data including: age, gender, BMI, current medications and history of sleep apnea will be collected. Data detailing the amount of drug administered during the procedure and any use of reversal agents, will be retrieved from the medical record. The study will be conducted within the Electrophysiology lab at Baystate Medical Center. An enrollment of 60 subjects is expected to be completed within 6 months. 30 patients will originate from the outpatient population and 30 from the inpatient. Follow up assessments using the OAAS scale will be completed at 30 min, 1 hour and 4 hours post procedure. Also, perioperative comfort and recall of DFT testing will be assessed at the 4 hour mark.

Detailed description

BACKGROUND Physician-guided moderate sedation, administered by a Registered Nurse has been the standard of practice for patients undergoing a wide range of electrophysiology procedures during the past decade. Currently a subjective sedation assessment tool is the standard of practice within the Electrophysiology Lab (EP Lab). Bispectral Index monitoring (BIS) is an objective measure of the depth of sedation presently employed at Baystate Medical Center in the Intensive Care Unit and within the department of anesthesia. AIM The aim of this research study is to assess the utility of BIS monitoring in measuring the depth of sedation in patients undergoing defibrillation threshold testing (DFT). Our primary endpoint is: A change in Observer's Assessment of Alertness/Sedation Scales (OAAS) scores of one point at the 30 minute data collection time period. Our secondary endpoints are: Lack of explicit recall of DFT testing and measurement of perioperative level of comfort. STUDY DESIGN AND SCOPE The population to be studied is those patients receiving a primary ICD implant or an ICD battery change with defibrillation threshold testing (DFT). All patients who have consented for ICD placement and DFT testing with moderate sedation will be invited to participate in this research study. Patients who are not candidates for DFT testing, as is determined by the EP physician, will be excluded from the study. Demographic data including: age, gender, BMI, current medications and history of sleep apnea will be collected. Data detailing the amount of drug administered during the procedure and any use of reversal agents, will be retrieved from the medical record. The study will be conducted within the Electrophysiology lab at Baystate Medical Center. An enrollment of 60 subjects is expected to be completed within 6 months. 30 patients will originate from the outpatient population and 30 from the inpatient. Follow up assessments using the OAAS scale will be completed at 30 min, 1 hour and 4 hours post procedure. Also, perioperative comfort and recall of DFT testing will be assessed at the 4 hour mark.

Conditions

Interventions

TypeNameDescription
DEVICEBispectral index monitoringThe monitoring of the EEG signal is designed to determine if the sedation is adequate.
OTHERRamsey Sedation ScaleThe determination of the degree of sedation is accomplished using an established sedation scale.

Timeline

Start date
2007-10-01
Primary completion
2013-08-01
Completion
2013-08-01
First posted
2008-09-09
Last updated
2016-10-19
Results posted
2016-10-19

Locations

1 site across 1 country: United States