The Effects of a Positive Expiratory Pressure (PEP) on Dyspnea and Dynamic Hyperinflation During Exercise in Chronic Obstructive Pulmonary Disease (COPD) Patients

The Effects of a Positive Expiratory Pressure (PEP) on Dyspnea and Dynamic Hyperinflation During Exercise in COPD Patients

Status
Unknown
Phase
N/A
Study type
Interventional
Enrollment
11 (estimated)
Sponsor
Khon Kaen University · Academic / Other
Sex
All
Age
70 Years
Healthy volunteers
Not accepted

Summary

From the relationship between pathophysiology of chronic obstructive pulmonary disease (COPD), dyspnea, and dynamic hyperinflation during ventilatory increasing, the investigators hypothesize that 1. Positive expiratory pressure (PEP) breathing will reduce dyspnea more than normal breathing during exercise in mild to moderate COPD patients. 2. PEP breathing will improve dynamic hyperinflation during exercise more than normal breathing in mild to moderate COPD patients. 3. PEP breathing will improve cardiorespiratory function during exercise than normal breathing in mild to moderate COPD patients.

Detailed description

Expiratory airflow limitation is the pathophysiological hallmark of chronic obstructive pulmonary disease (COPD) that leads to air trapping and increases in dynamic hyperinflation (DH) and consequently causes dyspnea during exercise. Although pursed lips breathing is a simple technique that provides a positive back pressure may retard the airway collapsed, but previous studies showed an unsuccessful reduction of DH which might cause by insufficient back pressure. And thereby a conical positive expiratory pressure (C-PEP) has been developed in our laboratory to generate back pressure higher than pursed lips breathing. Moreover, an effect of PEP on DH has not carried out in patient with COPD. Therefore, the objective of the present study was to examine effects of a C-PEP on DH and respiratory response during exercise in patient with COPD.

Conditions

Interventions

TypeNameDescription
DEVICEConical Positive Expiratory Pressure Device (C-PEP)Conical positive expiratory pressure device (C-PEP) in this study was designed on the principle of expiratory flow retardation. The principle occurs when exhaling through a small tube diameter, i.e. a small straw, pursed lip breathing, or positive expiratory pressure. Expiratory retardation, results from a decrease in tube diameter, creates flow resistance during exhalation. With flow resistance, the greater the flow the greater the back pressure, and the less the flow the lower the pressure. Expiratory retardation was applied in an attempt to facilitate exhalation and to relieve the air trapping. The optimal design was found to be: cone shape, proximal diameter is 2.0 cm, distal diameter is 0.6 cm, and length is 2.5 cm. Subjects will rest for 10-15 minutes until HR, BP are stabilized. They will undertake 15 min of alternating quadriceps exercise (30% 1 RM) either breathing with the C-PEP device.
OTHERControl breathingSubjects will rest for 10-15 minutes until HR, BP are stabilized. They will undertake 15 min of alternating quadriceps exercise (30% 1 RM) either breathing normally.

Timeline

Start date
2008-03-01
Primary completion
2009-02-01
Completion
2009-02-01
First posted
2008-08-26
Last updated
2008-11-14

Locations

1 site across 1 country: Thailand