Clinical Trials Directory

Trials / Completed

CompletedNCT00677014

Comparison of AV Optimization Methods Used in Cardiac Resynchronization Therapy (CRT)

SMARTDELAY Determined AV Optimization: A Comparison to Other AV Delay Methods Used in Cardiac Resynchronization Therapy

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
1,060 (actual)
Sponsor
Boston Scientific Corporation · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The primary objective of SMART-AV is to assess the effect of SmartDelay for determining optimal AV delay timing during CRT compared to both a fixed AV delay and echocardiography-determined optimal AV timing chronically over a 6-month period.

Detailed description

SMART-AV is a randomized, multi-center, double-blinded, non-significant risk, three-armed trial that will investigate the effects of optimizing AV delay timing in heart failure patients receiving CRT-D therapy. Patients will be randomized in a 1:1:1 ratio using randomly permuted blocks within each center. The study will compare chronic changes in structural and functional outcomes in CRT-D patients randomized to AV delay set as fixed, set with SmartDelay or determined by echocardiography. Patients will be followed at enrollment, implant, post-implant, 3-months post-implant and 6-months post-implant.

Conditions

Interventions

TypeNameDescription
DEVICEAV Delay programming through cardiac resynchronization therapyAll subjects in this trial receive the same device. For the purpose of this trial. "intervention" is programming of the atrio-ventricular (AV) delay in the two treatment arms, while the control arm will receive AV delay programming from a Fixed nominal setting. Echo optimized and Algorithm optimized are the treatment arms programmed to receive optimized AV delay settings and will be compared to the Fixed nominal arm.
DEVICEAV Delay programming through cardiac resynchronization therapyAll subjects in this trial receive the same device. For the purpose of this trial. "intervention" is programming of the atrio-ventricular (AV) delay in the two treatment arms, while the control arm will receive AV delay programming from a Fixed nominal setting. Echo optimized and Algorithm optimized are the treatment arms programmed to receive optimized AV delay settings and will be compared to the Fixed nominal arm.
DEVICEAV Delay programming through cardiac resynchronization therapyAll subjects in this trial receive the same device. For the purpose of this trial. "intervention" is programming of the atrio-ventricular (AV) delay in the two treatment arms, while the control arm will receive AV delay programming from a Fixed nominal setting. Echo optimized and Algorithm optimized are the treatment arms programmed to receive optimized AV delay settings and will be compared to the Fixed nominal arm.

Timeline

Start date
2008-05-01
Primary completion
2010-07-01
Completion
2010-07-01
First posted
2008-05-13
Last updated
2013-04-24
Results posted
2012-08-30

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT00677014. Inclusion in this directory is not an endorsement.