Clinical Trials Directory

Trials / Unknown

UnknownNCT00549380

Clinical Study of Aneurysm Exclusion

A Clinical Study of Aneurysm Exclusion Using Endologix, Inc. Endoluminal Technology

Status
Unknown
Phase
Phase 1
Study type
Interventional
Enrollment
88 (estimated)
Sponsor
Arizona Heart Institute · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The ultimate purpose is to explore potential techniques to exclude aneurysms and provide alternative conduit for arterial flow. The single center sponsorship is intended to provide the investigators the potential to incorporate improvements in existing technology during the course of the study thereby ultimately enhancing the potential for superior medical care of patients suffering from these disease states.

Detailed description

The primary objective of this study is to examine the feasibility of expanded applications of the basic Endologix technology for the treatment of arterial aneurysmal disease. A second objective of this study is to gather data in order to make logical, scientific recommendations for device design, construction and application which will expand the application of the endoluminal graft technology and improve its safety and efficacy while expanding the several potential future positive aspects of a less invasive method of treating arterial occlusive disease. Endologix, Inc. has applied for and received an IDE for the investigation of a bifurcated device to exclude aneurysms of the abdominal aorta. The Arizona Heart Institute experience indicates that this small study design will prove successful. Using the basic technology of the current approved IDE, it is Arizona Heart Institute's intention to expand the scope of application and design in order to address a greater population basis suffering from aneurysmal disease. In this regard, the basic Endologix device designs will be applied to appropriate patients beyond the scope of the current bifurcated IDE. Patients meeting the criteria for the Endologix IDE will be enrolled independently in that study and followed precisely in order to comply with the study design. Patients with aneurysmal disease not currently filling the criteria for a bifurcated abdominal aortic prosthetic but who could potentially benefit from the technology to exclude aneurysmal disease will be considered from this study. The patient's participation in the Study will include enrollment, Investigational Device procedure and follow-up period. Patient data will be collected for 1, 6, and 12 months and beyond as indicated. Subject follow-up at 1 month will include; ABIs, a complete Physical Examination, Duplex Ultrasound, and X-ray. Subject follow-up at 6 and 12 months will also include ABIs, a complete Physical Examination, CT Scan-Contrast Enhanced (unless contraindicated), CT Scan-No Contrast, and X-ray.

Conditions

Interventions

TypeNameDescription
DEVICEEndologix, Inc. Endoluminal TechnologyStent-graft endoprosthesis is inserted by Delivery System via a surgical cutdown (e.g., external iliac artery, femoral artery, common iliac artery conduit, etc.) approach. The insertion method depends on each patient's anatomy and is determined by the Clinical Investigator.

Timeline

Start date
1999-10-01
Primary completion
2010-10-01
Completion
2010-10-01
First posted
2007-10-25
Last updated
2010-05-27

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT00549380. Inclusion in this directory is not an endorsement.