Clinical Trials Directory

Trials / Completed

CompletedNCT00473772

DEBlue Stent vs Cypher Stent in the Treatment of Advanced Coronary Artery Disease

Paclitaxel-Eluting PTCA-Balloon in Combination With the CoroflexTM Blue Stent vs the Sirolimus Coated CypherTM Stent in the Treatment of Advanced Coronary Artery Disease

Status
Completed
Phase
Phase 1 / Phase 2
Study type
Interventional
Enrollment
643 (actual)
Sponsor
University Hospital, Saarland · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

The aim of the study is to assess the safety and efficacy of the Paclitaxel-eluting SeQuent Please S stent system (DEBlue) in the treatment of stenoses in native coronary arteries with nominal stent diameters between ≥ 2.5 mm and ≤ 3.5 mm and \< 24 mm in length for procedural success and preservation of vessel patency in comparison to the Sirolimus-eluting CypherTM stent.

Detailed description

The incidence of in-stent restenosis after percutaneous coronary intervention varies between 5 and 35% after bare metal stenting and is as high as 19% after the implantation of a drug-eluting stent in patients at moderate risk. Restenosis due to neointimal hyperplasia is a slow process, suggesting that therapeutic local drug administration would need to be prolonged to be beneficial. Stent-based local drug delivery provides sustained drug release using special release technologies like polymer coating. However, cell culture experiments indicate that even brief contact between vascular smooth muscle cells and lipophilic taxane compounds can inhibit vascular smooth muscle cell proliferation for a long period. In experiments in swine, intracoronary delivery of paclitaxel by contrast media or by a drug-coated balloon catheter was found to result in vascular tissue concentrations capable of producing antiproliferative effects, thus leading to a significant reduction in neointimal proliferation. In these animal studies, the most pronounced reduction of neointimal formation was seen with paclitaxel-coated balloon catheters.

Conditions

Interventions

TypeNameDescription
DEVICEDEBlue stent vs. Cypher stentDES vs. DEB with BMS

Timeline

Start date
2007-07-01
Primary completion
2008-10-01
Completion
2011-01-01
First posted
2007-05-15
Last updated
2014-05-06

Locations

16 sites across 8 countries: Belgium, Czechia, France, Germany, Netherlands, Spain, Sweden, United Kingdom

Source: ClinicalTrials.gov record NCT00473772. Inclusion in this directory is not an endorsement.