Trials / Completed
CompletedNCT00462839
Accuracy of Blood Loss Estimation After Vaginal Delivery
The Accuracy of Blood Loss Estimation After Simulated Vaginal Delivery
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 106 (actual)
- Sponsor
- Northwestern University · Academic / Other
- Sex
- All
- Age
- 18 Years – 65 Years
- Healthy volunteers
- Accepted
Summary
Post-partum hemorrhage (PPH) is defined as blood loss greater than 500 mL after vaginal delivery. Delayed diagnosis of PPH is a major cause of maternal morbidity and mortality. Obstetricians estimate blood loss at delivery by visual estimation of blood collected in the obstetric drapes. Blood is often mixed with urine and surgical sponges. The urine, blood, and sponges collect in a cone shaped plastic bag that is suspended from the perineum during delivery. Visual estimation of blood loss is insensitive in diagnosing PPH. In one study visual assessment of blood loss underestimated postpartum blood loss by 33% to 50% compared to an objective measurement of blood loss using photospectrometry. Other studies have shown that the magnitude of underestimation increases as the amount of blood loss is increased. A limitation of previous studies is that there is no "gold standard" for blood loss determination in the third stage of labor. Care providers (obstetricians, anesthesiologists, and labor \& delivery nurses) need to be able to accurately estimate blood loss in order to better care for mothers and prevent morbidity and mortality. It is unknown whether provider type or experience (obstetric and anesthesiology resident, fellow, attending physicians, and nurses) influences the accuracy of blood loss estimation, or whether blood loss estimation can be improved by providing graduated markings on the vaginal delivery drape.
Detailed description
Packed red blood cells discarded by the blood bank will be mixed with normal saline to simulate whole blood with a hematocrit of 33%. A total of eight isolated study stations will be set up (study participants will only be able to visualize the vaginal delivery drape for one station at a time). The simulated blood will be mixed with urine and sponges and be placed in suspended blood collection drapes which are used during vaginal deliveries at Northwestern Memorial Hospital. Two types of drapes will be used: drapes without calibrated markings and drapes with calibrated markings. Calibrated volume markings will begin at 500 mL at 500 mL intervals to 2500 mL. Study participants will be randomized to one of two groups. Randomization will occur in blocks depending on provider type. Group 1 will view the unmarked vaginal collection drapes first and Group 2 will view the collection drapes with the calibrated markings first. Both groups will analyze the initial four study stations in random order. At the completion of the four study stations, the group which evaluated the drapes without markings will cross over to view the stations with calibrated markings and the group that views uncalibrated drapes will then view the calibrated drapes. Each study participant will view a station and write his/her estimation of blood loss on a data card. Study participants will NOT be allowed to change answers once they have been recorded. Demographic data on study participants will include provider type, level of training/years of practice, and gender.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| PROCEDURE | blood loss estimation | Participants were randomized in blocks, by provider type to view either the four calibrated stations or the four non-calibrated stations. The order of the volumes within each set of stations was randomized. Participants received a data card for each station on which they wrote the volume estimated. After each station, the data card was collected. Alterations to the estimations were not allowed once the answers were recorded. Subjects were then crossed over to the other group and asked to estimate the blood volumes in the non-calibrated drapes if they had first viewed the calibrated drape or the calibrated drape if they had viewed the non-calibrated drape. The order of viewing the four volumes was again randomized. The volumes were the same at the corresponding station for the calibrated and non-calibrated stations so the impact of the calibration markings on accuracy could be determined. |
Timeline
- Start date
- 2006-07-01
- Primary completion
- 2008-04-01
- Completion
- 2008-04-01
- First posted
- 2007-04-19
- Last updated
- 2014-04-14
- Results posted
- 2011-12-09
Locations
1 site across 1 country: United States
Source: ClinicalTrials.gov record NCT00462839. Inclusion in this directory is not an endorsement.