TerminatedNCT00440791

Evaluation of the PillCam™ Colon Capsule Endoscopy (PCCE) in the Visualization of the Colon

Status
Terminated
Phase
Study type
Observational
Enrollment
40 (actual)
Sponsor
Medtronic - MITG · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

This multi-center, prospective, cohort study of 394 subjects that are indicated for standard colonoscopy due to suspected or known colonic disease examines the Given Diagnostic System and the PillCam Colon Capsule in comparison to standard colonoscopy. This study aims a. To evaluate and compare the accuracy of PillCam ™ Colon capsule endoscopy (PCCE) with standard colonoscopy. This study will evaluate the safety of PillCam ™ Colon capsule endoscopy (PCCE)

Detailed description

The Given® Diagnostic System offers an alternative approach for endoscopic visualization of the colon using capsule endoscopy, a swallowable device which contains imagers, light sources, a power source and a RF transmitter. Advantages of the Given® Diagnostic System include the elimination of the need for conscious sedation, the minimally invasive, painless nature of the exam, and the ability to pursue normal daily activities immediately following the procedure . This multi-center prospective, cohort study will evaluate the performance of PCCE in visualizing the colon. Up to 394 subjects will participate in this study. All subjects to be enrolled will be appropriate candidates for standard colonoscopy based on their clinical indication. Each subject will undergo PCCE. All generated PCCE RAPID videos will be reviewed by blinded PCCE reading physicians. All readers, experienced in PillCam SB, will have undergone standardized training and passed a qualification test specific to reading and interpreting PCCE videos. Training will be done by reading at least 5 cases to demonstrate proficiency in interpretation of PCCE. PCCE results will be compared with that of a colonoscopy procedure. Following PCCE procedure, standard colonoscopy will be performed by a colonoscopist blinded to the results of the PCCE. The colonoscopist will be "unblinded" during the standard colonoscopy procedure at three locations on withdrawal of the colonoscope. Primary Endpoint - Accuracy parameters (sensitivity, specificity, NPV, PPV) of PCCE compared to standard colonoscopy. • Number, type and severity of adverse events with both PCCE and standard colonoscopy

Conditions

Interventions

TypeNameDescription
DEVICEPillCam Colon capsule endoscopy

Timeline

Start date
2006-06-01
Completion
2007-07-01
First posted
2007-02-27
Last updated
2019-07-31

Locations

7 sites across 2 countries: United States, Israel