Clinical Trials Directory

Trials / Completed

CompletedNCT00428285

Tolerability, Safety, & Efficacy of Argon Plasma Coagulation to Treat Anal Intraepithelial Neoplasia in HIV-Positive Men

A Phase II, Prospective, Open-label, Pilot Study of the Tolerability, Safety, and Efficacy of Argon Plasma Coagulation for the Treatment of Anal Intraepithelial Neoplasia Grade 2 or 3 in HIV-positive Men Having Sex With Men

Status
Completed
Phase
Phase 2
Study type
Interventional
Enrollment
20 (actual)
Sponsor
Centre hospitalier de l'Université de Montréal (CHUM) · Academic / Other
Sex
Male
Age
18 Years – 65 Years
Healthy volunteers
Not accepted

Summary

The purpose of this study is to assess if argon plasma coagulation (APC) is a safe and well tolerated treatment method for anal intraepithelial neoplasia (AIN) grade 2/3 in HIV-positive men having sex with men (MSM).

Detailed description

HIV infected men having sex with men (MSM) are at increased risk of developing anal cancer compared to the general population and the incidence continues to increase despite better control of HIV infection with HAART (Highly Active Anti-Retroviral Therapy). The causative agent is known to be Human Papilloma Virus infection which can lead to dysplastic changes in the anus, detectable by High Resolution Anoscopy with biopsies. The analysis of the abnormal tissue can then be graded as Anal Intraepithelial Neoplasia 1 to 3, with AIN 2 or 3 considered as high grade dysplasia. These lesions are cancer precursors, but the proportion of lesions progressing to invasive anal cancer and the time to event are unknown. There is currently no recognized treatment to offer as standard of care although it is of general belief that treating these lesions, as it is done for women with CIN 2 and 3 (Cervical Intraepithelial Neoplasia) could help decrease the number of progressions to invasive anal cancer in MSM infected with HIV. By experience at our center and results of this technique for other gastrointestinal pathologies, we believe Argon Plasma Coagulation (APC) could be a safe, well tolerated and efficient treatment of high-grade dysplasia (AIN 2/3) in HIV infected MSM. This study will assess the APC treatment in 20 patients, all HIV infected MSM, with established AIN 2/3 (as confirmed with their last two anal biopsies, at least 4 months apart). Patients will then be followed with regular High Resolution Anoscopies for two years. The primary objective is to assess if APC is a safe and well tolerated treatment method for AIN 2/3 in HIV-positive MSM. As secondary objectives, the efficacy of APC treatment on AIN 2/3 lesions in HIV-positive MSM, the number of treatments with APC necessary to obtain regression or resolution of AIN 2/3 over two years and the efficacy of APC treatment to decrease anal HPV in this population will also be addressed.

Conditions

Interventions

TypeNameDescription
PROCEDUREArgon Plasma CoagulationArgon Plasma Coagulation (APC) is a non-contact electrosurgical technique delivering a high-frequency electrical current through ionized argon gas i.e. the argon plasma. This current produces a zone of coagulation, desiccation, and devitalisation 2-3 mm deep. Patients will be offered up to 3 treatments if recurrence occur after the first two.

Timeline

Start date
2007-02-01
Primary completion
2010-02-01
Completion
2016-07-01
First posted
2007-01-29
Last updated
2019-05-01

Locations

2 sites across 1 country: Canada

Source: ClinicalTrials.gov record NCT00428285. Inclusion in this directory is not an endorsement.