Safety and Efficacy of Express LD to Treat Stenosed or Occlusive Atherosclerotic Disease in Iliac Arteries

A Prospective, Multicenter, Single Arm Study to Obtain Additional Data on the Safety and Efficacy of the Express Vascular LD Implantation in the Treatment of Stenosed or Occlusive Atherosclerotic Disease in Iliac Arteries

Status
Completed
Phase
Phase 3
Study type
Interventional
Enrollment
150 (planned)
Sponsor
Boston Scientific Corporation · Industry
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

To obtain additional data on safety and efficacy of the Express stent implantation in the treatment of stenosed or occlusive atherosclerotic disease (de novo or restenotic lesions) in the iliac arteries (common or external).

Detailed description

This study was conducted to provide additional data on the safety and efficacy of the Express™ Vascular LD stent, particularly with regard to the long-term patency in iliac arteries. The study would provide data on angiographic endpoints and clinical outcomes at 30 days, 6 months, and at 12 and 24 months post implantation in atherosclerotic lesions in iliac arteries. The data obtained in this study with the use of the Express™ Vascular LD stent was compared with historical data obtained from the use of the Palmaz balloon-expandable stent. The Palmaz balloon expandable stent has been chosen as the control device because it is currently the only FDA-approved balloon-expandable stent for use in the percutaneous treatment of atherosclerotic disease in iliac arteries. The Palmaz balloon-expandable stent is no longer commercialized in Europe. Therefore a randomized study with the Palmaz balloon-expandable stent was not feasible. In addition, there are no ongoing or published randomized trials describing performance of a newer version of the Palmaz stent in iliac atherosclerotic lesions. In order to adequately compare the efficacy data of the ExpressTM Vascular LD stent with the efficacy data of the Palmaz balloon-expandable stent, the same efficacy parameter as in the publication on the Palmaz balloon-expandable stent was measured in this study: % mean loss of the luminal diameter at 6 months post-procedure. The findings of the longer-term Follow-Up assessments at 12 and 24 months will be presented as the results from these assessments become available.

Conditions

Interventions

TypeNameDescription
DEVICEstent implantation

Timeline

Start date
2004-01-01
Primary completion
2005-07-01
Completion
2007-02-01
First posted
2006-07-14
Last updated
2008-09-29

Locations

10 sites across 5 countries: Belgium, Canada, Czechia, Netherlands, Poland

Source: ClinicalTrials.gov record NCT00352222. Inclusion in this directory is not an endorsement.