Clinical Trials Directory

Trials / Completed

CompletedNCT00288847

Functional Surface Electromyogram of Knee Extensors in Healthy Humans and Patients With Patella-dislocation.

Status
Completed
Phase
Study type
Observational
Enrollment
15 (actual)
Sponsor
University Hospital, Basel, Switzerland · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Accepted

Summary

The activation of the knee extensors in adults after patella dislocation. The kneecap can dislocate due to an accident or also only due to an interior turn in the stretched knee joint out of its sliding bearing. E. Arendt (Arendt 2002) wrote an overview work, in which possible causes and working methods to the patella dislocation are discussed. Despite almost one hundred quotations the authors are not able find the causes and the possible treatment concepts. The study will examined healthy adults (25 female and 25 men) and 25 patients with patella dislocation by a routine applied clinical gait analysis and surface EMG (after the European SENIAM guidelines) iin the Laboratory for Gait Analysis Basel of the Children's University Hospital Basel. The combination of gait analysis and the surface EMG with Wavelet analysis may objectify possible reasons for a patella dislocation

Detailed description

Introduction The kneecap can dislocate due to an accident or also only due to an interior turn in the stretched knee joint out of its sliding bearing. E. Arendt (Arendt 2002) wrote an overview work, in which possible causes and working methods to the patella dislocation are discussed. Despite almost one hundred quotations the authors are not able find the causes and the possible treatment concepts. The study will examined healthy adults (25 female and 25 men) and 25 patients with patella dislocation by a routine applied clinical gait analysis and surface EMG (after the European SENIAM guidelines) in the Laboratory for Gait Analysis Basel of the Children's University Hospital Basel. The combination of gait analysis and the surface EMG with Wavelet analysis may objectify possible reasons for a patella dislocation and compare the intensity pattern of the EMG between the groups. Method All subjects (healthy and patients with a patella dislocation) will be prior to the study informed about the study and sign the consent from The investigation will include the following tasks: * Preparation of the subject for a clinical gait analysis with placing reflecting marker on the lower body according to the maker setup of Davis et al. (Davis III et al., 1991. * Preparation of the subject for a surface EMG of the muscles: gastrocnemius medialis, tibialis anterior, vastus medialis, vastus lateralis, rectus femoris, biceps femoris, semitendinosus according to the SENIAM-Standard. * Measurements: 10 trials of level walking in self selected speed and 3 times 5 single leg quads on the force plate. * System: VICON 460 (6 Cameras, 120 Hz, Oxford Metrics Ltd., UK). * EMG-System: Zebris, Tuebingen, Germany; Amplifiers: Biovision, Wehrheim, Germany, EMG-Electrodes: Bipolar Ag/AgCl Surface Electrodes Noraxon, Sampling rate: 2520 Hz * Data analysis: Kinetic-and kinematic data with the Vicon-Software, EMG-Data with Wavelet Package (Biomechanigg, Calgary, Canada) * Statistical Analysis: ANVOA

Conditions

Timeline

Start date
2005-11-01
Primary completion
2007-12-01
Completion
2007-12-01
First posted
2006-02-08
Last updated
2015-09-22

Locations

1 site across 1 country: Switzerland

Source: ClinicalTrials.gov record NCT00288847. Inclusion in this directory is not an endorsement.