Clinical Trials Directory

Trials / Completed

CompletedNCT00272194

Ambu® Laryngeal Mask as an Intubation Conduit

The Ambu® Laryngeal Mask as an Intubation Conduit For Patients Undergoing Routine General Anesthesia

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
160 (planned)
Sponsor
The University of Texas Health Science Center, Houston · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers
Accepted

Summary

The purpose of this study is to determine if the Ambu Laryngeal Mask can be used as an intubation conduit for endotracheal intubation.

Detailed description

The laryngeal mask airway (LMA) is an established supra-glottic device that provides better ventilation than traditional mask ventilation and is less invasive than endotracheal intubation. Being less invasive, it is commonly used for short elective surgical procedures. Its ability to be both easily and rapidly inserted also makes it useful as a rescue device in difficult and failed intubations. Being a supra-glottic device, the LMA does not protect patients from regurgitation and aspiration. Additionally, patients requiring alternative positions, such as prone or lateral, or those having surgery in the neck/head area are contra-indicated for LMA use due to risk of possible movement of the LMA, and therefore possible loss of airway patency. Thus, the LMA can be utilized as an intermediary method of airway management to endotracheal intubation. The manufacturer of the reusable LMA-ClassicTM states that "the success rate of intubation through the standard LMA-ClassicTM is highly variable (30-93%)," whereas the success rate of the disposable version, LMA-UniqueTM, has been found to be only 21%1. An LMA specifically designed for intubation now exists and improves the success rate of intubation. The reusable LMA-FastrachTM or Intubating-LMATM (ILMA) is a rigid and anatomically curved airway tube. It is wide enough to accommodate 8.0 mm cuffed endotracheal tubes. Attached to the ILMA is a rigid handle to aid in one-handed insertion, removal, and adjustment. Success rates for intubating through the ILMA are 96.5% when inserted blindly and 100% with fiberoptic guidance2. No disposable version of the ILMA presently exists. The Ambu® Laryngeal Mask (ALMA) is a new disposable laryngeal mask with an anatomical curve similar to the ILMA. The reasons for the use of disposable products can be many and varied. The residual risk of the transmission of germs and protein particles represents one indication. If supra-glottic airway devices are used electively or in emergencies, e.g. for HIV-positive patients or those infected with Creutzfeldt-Jacob disease, reuse of the products is not desirable. Disposable products, on the other hand, offer the benefit that the transmission of germs is avoided, and at the same time offer considerable economic advantages due to the much lower price of the product. The disposable ALMA has been proven as an effective and safe supra-glottic airway device3. Upon fiberoptic visualization through its shaft, the glottis was visualized 91.5% of the time, indicating that this device may be used as an intubation conduit. The purpose of this study is to determine if the ALMA is also safe and effective as an intubating conduit. The hypothesis is that the ALMA will perform as well as, if not better than the LMA-UniqueTM.

Conditions

Interventions

TypeNameDescription
DEVICEAmbu Laryngeal Mask
DEVICEAintree Exchange Catheter
DEVICELaryngeal Mask Airway

Timeline

Start date
2005-12-01
Completion
2007-04-01
First posted
2006-01-04
Last updated
2016-03-23

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT00272194. Inclusion in this directory is not an endorsement.