Clinical Trials Directory

Trials / Completed

CompletedNCT00253838

A Comparison of Two Type of Stems in Revision Hip Arthroplasty

A Randomized Controlled Trial Comparing a Titanium to a Cobalt Chrome Femoral Stem in Revision Hip Arthroplasty: A Pilot Study

Status
Completed
Phase
N/A
Study type
Interventional
Enrollment
39 (actual)
Sponsor
Ottawa Hospital Research Institute · Academic / Other
Sex
All
Age
21 Years
Healthy volunteers
Not accepted

Summary

This study compares two different hip stem components. Both hip stems used in this study allow the femur bone to attach and grow into them for stability. The main difference between the two stems is that one of the stems, the Solution® Stem, is made from Cobalt Chrome, a type of metal, and does not have a hydroxylapatite (HA) coating, while the second stem included in the study, the Restoration hip stem, is made from titanium alloy, a different type of metal that has a roughened surface and allows for a hydroxylapatite (HA) coating to be applied to the entire length of the stem. The HA coating is a thin calcium phosphate layer on the stem to encourage the bone to grow into it. We are trying to see if there is any difference in the initial bony ingrowth between the two stems and to compare the results in patients over the first two years after the surgery and then again at the five-year period.

Detailed description

Revision total hip arthroplasty is becoming increasingly common due to the large number of primary total hip arthroplasties being performed annually. Failure of these arthroplasties has led to an increasing number of patients requiring revision arthroplasty. Various methods have been used to reconstruct the hip during a revision procedure. These have generally consisted of a cemented or uncemented femoral stem. It is now generally accepted that uncemented femoral stems have improved results over cemented stems, especially in those cases with compromised bone stock. There are two main alloys used for the femoral revision component, that is cobalt chrome and titanium. There may be certain advantages to the use of titanium, in particular, a reduction in future bone loss caused by stress shielding. Stress shielding is commonly seen with cobalt chrome implants. In order to assess this and the overall survival of these two different implants a randomized clinical trial is proposed.

Conditions

Interventions

TypeNameDescription
PROCEDURERestoration HA stemThe Restoration hip stem, is made from titanium alloy, a different type of metal that has a roughened surfacing and allows for a hydroxylapatite (HA) coating to be applied to the entire length of the stem.
PROCEDURESolution stemThe Solution stem is made from Cobalt Chrome, a type of metal, and does not have a hydroxylapatite (HA) coating.

Timeline

Start date
2001-10-01
Primary completion
2010-09-01
Completion
2012-03-01
First posted
2005-11-15
Last updated
2017-09-25

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT00253838. Inclusion in this directory is not an endorsement.