Clinical Trials Directory

Trials / Completed

CompletedNCT00182338

Evaluation of Volume Status in Peritoneal Dialysis Patients

Status
Completed
Phase
Study type
Observational
Enrollment
22 (actual)
Sponsor
McMaster University · Academic / Other
Sex
All
Age
18 Years
Healthy volunteers
Not accepted

Summary

Patients with kidney failure on dialysis have a much higher risk of developing cardiovascular disease as compared to the general population. Recently, two large studies have shown that increasing the amount of dialysis does not decrease cardiovascular disease. It is known that retaining too much fluid leads to high blood pressure and thickening of the heart wall. Peritoneal dialysis is a method of home dialysis which allows dialysis patients autonomy and independence. This study will measure blood levels of a protein called N-BNP and measure the extent of body fluid by a machine called a bioimpedance analyzer. This device administers an undetectible electric current which distributes throughout total body water. The relationship between these tests and the clinical presence of volume expansion will be assessed. In addition, the extent of total body fluid and it's impact on heart attacks, heart failure and stroke will be determined.

Detailed description

Patients with end-stage renal disease (ESRD) have a higher risk than the general population of developing premature cardiovascular disease; the reasons for this are complex. Two recent randomized controlled trials in peritoneal dialysis patients have demonstrated that targeting patients to higher dialysis clearance values is not associated with a reduction in mortality. It is known that patients on peritoneal dialysis are more likely to be volume expanded, develop left ventricular hypertrophy, and have inadequate blood pressure relative to patients on hemodialysis. As a result there has been increased attention on the role of fluid management in reducing the risk of developing congestive heart failure and other adverse cardiovascular events in peritoneal dialysis patients. Extracellular fluid volume and total body water can be accurately assessed with multi-frequency bioimpedance analysis (BIA). Estimation of volume expansion by measuring the natriuretic peptide N-BNP produced by cardiac tissue in response to ventricular wall stretch can also be used. The purpose of this study is to determine whether volume status, as measured by BIA and N-BNP levels, correlates with clinical volume assessment, cardiovascular outcomes, peritoneal membrane transport properties and markers of inflammation such as serum albumin and C-reactive protein.

Conditions

Timeline

Start date
2005-01-01
Primary completion
2009-01-01
Completion
2009-01-01
First posted
2005-09-16
Last updated
2011-07-20

Locations

1 site across 1 country: Canada

Source: ClinicalTrials.gov record NCT00182338. Inclusion in this directory is not an endorsement.