Trials / Completed
CompletedNCT00180492
Post-Approval Study of the Guidant Carotid Stent Systems and Embolic Protection Systems: CAPTURE
Carotid RX ACCULINK(TM)/ACCUNET(TM) Post-Approval Trial to Uncover Unanticipated or Rare Events - CAPTURE
- Status
- Completed
- Phase
- N/A
- Study type
- Interventional
- Enrollment
- 1,500 (planned)
- Sponsor
- Abbott Medical Devices · Industry
- Sex
- All
- Age
- —
- Healthy volunteers
- Not accepted
Summary
This purpose of this study is to collect data on the FDA-approved ACCULINK(TM) Carotid Stent System and FDA 510(k)-cleared ACCUNET(TM) Embolic Protection System for the treatment of patients with atherosclerotic disease, when used by physicians under commercial use conditions.
Detailed description
CAPTURE is a post-approval study to collect information on the safety and effectiveness of the ACCULINK and ACCUNET since the approval/clearance of these devices by the FDA. The ACCULINK stent is an elastic-like metal tube that is used to hold open a narrow part of a blood vessel. The ACCUNET is a wire mesh basket that is placed in the vessel to catch material (blood clots, fatty material) that could break off from the narrowed area of the blood vessel and block blood flow downstream during the stent procedure. Another goal of the CAPTURE study is to confirm that the ACCULINK and ACCUNET can be used safely by physicians with varying levels of experience in stenting procedures. The basis for FDA's approval/clearance of the ACCULINK and ACCUNET was the ARCHeR trials (ACCULINK/ACCUNET for Revascularization of Carotids in High-Risk Patients). The ARCHeR trials were conducted to collect data on the safety and effectiveness of the ACCULINK and ACCUNET when used in the treatment of carotid artery disease in patients at high risk for surgical treatment (carotid endarterectomy) because of medical or surgical comorbidities. The ARCHeR trials showed that the ACCULINK, used with or without the ACCUNET, is a safe and effective treatment option based on the rate of death, stroke, and myocardial infarction at 30 days, and stroke at one year.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | RX ACCULINK(TM) Carotid Stent System and RX ACCUNET(TM) Embolic Protection System |
Timeline
- Start date
- 2004-10-01
- Primary completion
- 2006-12-01
- Completion
- 2007-08-01
- First posted
- 2005-09-16
- Last updated
- 2008-10-29
Locations
1 site across 1 country: United States
Source: ClinicalTrials.gov record NCT00180492. Inclusion in this directory is not an endorsement.