CompletedNCT00178555

Comparison of the Video and Macintosh Laryngoscope in Patients Who May be Difficult to Intubate

A Comparison of Laryngoscopy Techniques Using the Video Laryngoscope and the Traditional Macintosh Laryngoscope in Patients Who May be Difficult to Intubate

Status
Completed
Phase
Phase 4
Study type
Interventional
Enrollment
200 (planned)
Sponsor
The University of Texas Health Science Center, Houston · Academic / Other
Sex
All
Age
18 Years – 80 Years
Healthy volunteers

Summary

The purpose of this study is to determine if the Video Laryngoscope (VL) is a useful instrument in patients at risk for difficult intubation. We will compare this device to the traditional Macintosh Laryngoscope.

Detailed description

Despite improvements made to the traditional laryngoscope blade since its invention, occasionally intubation of the trachea cannot be accomplished with facility, even in patients with anatomy that does not predict difficult intubation. It is estimated that endotracheal intubation is performed on some 8 million patients per year in the United States. Of these endotracheal intubations, approximately 80% are performed by direct laryngoscopy with transoral placement of the endotracheal tube (ET) into the trachea. There is fairly uniform reporting of the incidence of failed intubation in the literature; it occurs in approximately 0.05% or 1:2230 of surgical patients and in approximately 0.13% to 0.35%, or 1:750 to 1:280, of the obstetric patients. The incidence of unsuspected difficult intubation is estimated to be higher at 3%. One factor that contributes to difficult intubation is poor visualization. The VL is designed to optimize visualization by presenting to the operator an enlarged video image of airway structures. In contrast, using conventional laryngoscopy, anesthesiologists have only a "keyhole" view of the airway structures; a view that may be further obscured during attempts to pass the ET. The VL consists of a laryngoscope handle and Macintosh blade that have been modified to provide a video image of airway structures on a screen, which can be conveniently located directly in front of the anesthesiologist. A micro video module is contained in the modified handle. An image/light bundle is introduced into the standard blade. This system has been previously tested in which the consensus was that the device is extremely easy to learn to use because most anesthesiologists are familiar with the use of the Macintosh blade. It has also been useful in the instruction of laryngoscopy by non-anesthesiologists. There are several potential advantages of a video image in the context of direct laryngoscopy. The system provides high quality video images that are enlarged on the video monitor for easier visualization. If laryngeal manipulation is required to improve visualization of laryngeal structures, the intubator and the person assisting can coordinate movements as they observe, simultaneously, the image on the video monitor. With the video image projected from the distal end of the laryngoscope blade, laryngeal structures are kept in view as the ET is passed through the oropharynx into the trachea. Comparison: Video Laryngoscope as a conduit for possible difficult intubation compared to the traditional Macintosh blade.

Conditions

Interventions

TypeNameDescription
DEVICEDCI Video Intubation System-Macintosh Laryngoscope
DEVICEMacintosh Laryngoscope

Timeline

Start date
2003-08-01
Primary completion
2007-02-01
Completion
2007-02-01
First posted
2005-09-15
Last updated
2016-03-23

Locations

1 site across 1 country: United States

Source: ClinicalTrials.gov record NCT00178555. Inclusion in this directory is not an endorsement.