Trials / Completed
CompletedNCT00116948
A Comparison of Two Total Hip Replacements: Hip Resurfacing System Versus Mallory-Head/Exeter
- Status
- Completed
- Phase
- Phase 4
- Study type
- Interventional
- Enrollment
- 50 (estimated)
- Sponsor
- University of Aarhus · Academic / Other
- Sex
- All
- Age
- 50 Years – 65 Years
- Healthy volunteers
- Not accepted
Summary
The purpose of this study is to compare two total hip replacement systems: Hip Resurfacing System (ReCap) versus Mallory-Head/Exeter.
Detailed description
In Denmark approximately 7000 primary hip replacements are implanted yearly, and the incidence is rising with the increasingly aging population. For older patients, the incidence of later revisions of hip implantation is low. Unfortunately, this is not true for younger patients. Approximately 20% of patients under 55 years of age at the time of surgery must have the hip implant renewed within 10 years. This is primarily because of the wear generated by polyethylene debris. The polyethylene is associated with osteolysis in the proximity of the prosthesis leading to failure of the prosthesis. This unsatisfactory result has led to the development of an alternative hip prosthesis especially to benefit younger and physically active people. The new prosthesis should produce less inflammatory debris and less osteolysis induced failure. To avoid the polyethylene particles, a new type of prosthesis has been made articulating metal on metal. The Hip Resurfacing System consists of an alloy of chrome - cobalt - molybdenum. Another point of interest for this prosthesis is also the size of the articulating surfaces which are bigger than usual. This will theoretically participate in the generation of metal ions. Study objectives: * This randomised prospective study will investigate the emission of Co-, Cr- and Mb-ions from Hip Resurfacing System and Mallory-Head/Exeter implants, respectively. The emission is measured as the ion concentration in the urine and is correlated to the inflammatory response in fasting plasma before and after the operation. * To assess the walking pattern postoperatively using a 3D gait analysis, Vicon Polygon. * To assess the postoperative recovery using the Harris hip score and visual analogue scale. * The migration of acetabular components will be evaluated by RSA, performing radiostereometric analyses at the Orthopaedic Center, Aarhus University Hospital. The follow-up RSA will be scheduled for week 1, as well as 3 months, 12 months, 24 months, and 5 years after surgery. Bone mineral density around the implanted femoral component will be examined by DEXA scan at week 1, as well as 1 year and 2 years after surgery.
Conditions
Interventions
| Type | Name | Description |
|---|---|---|
| DEVICE | ReCap, Hip resurfacing system, Biomet | ReCap total hip arthroplasty inserted according to manufactures manual. |
Timeline
- Start date
- 2005-01-01
- Primary completion
- 2011-09-01
- Completion
- 2012-01-01
- First posted
- 2005-07-01
- Last updated
- 2014-12-05
Locations
1 site across 1 country: Denmark
Source: ClinicalTrials.gov record NCT00116948. Inclusion in this directory is not an endorsement.